BARR500
TECHNICAL DATA
OPERATOR
Electric motor
Supply voltage
Motor power supply
Power absorbed
Operating temperature
Degree of protection
Limit switch
Operating frequency (%Fu) at 20°C
Maximum boom length
Opening time to 90°
Operating temperature
Load-bearing structure protection
Load-bearing structure coating
Load-bearing structure dimensions
Operator weight
Formula to calculate the
operating frequency
Maximum operating curve
The operating time based on the desired operating frequency can be derived from the graphs (2) and (3).
NOMENCLATURE
Referring to figure 4.
1 - Upright
2 - Foundation plate
3 - Spring
4 - Balancing device with Cable
5 - Electric motor
6 - Reduction gear
7 - Adjustable limit switch disc
8 - Electronic control unit container
9 - Hall-effect sensor
10 - Boom
11 - Spring adjustment nuts
DIMENSIONS
Referring to Figures 5, 6 and 7.
BARR524
24Vdc 1600 RPM
220/230Vac, single-phase, 50-60Hz
24Vdc
MAX 150W
-20°C +60°C
2 limit switches (open/close)
50%
6m
5s
%Fu=
A = Opening time
C = Closing time
P = Overall pause time
A + C + P = Time between two openings
BARR526
24Vdc 3350 RPM
MAX 200W
-20°C +60°C
IP 44
2 limit switches (open/close)
-20°C +60°C
Cataphoresis
RAL 7040 polyester
1117x325x255
45 Kg (as sold)
A + C
x100
A + C + P
35
UK
24Vdc
60%
2m
1.8s