Default Settings; Language Selection; Delay Start - Verderdos ME - DUAL - PH/CL Manual De Regulatión

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PASSWORD = 0 (PASSWORD not programmed)
pH Stability = NO (deactivated)
Start Delay: 0 minutes
pH:
 Operation Type: Proportional
 SETPOINT: 7.3 pH
 Proportionality:1pH
 Regulation direction: Acid (pH - )
 Flowrate: 80% (120 imp/min)
 Alarm Time : 0unit (disabled)
DEFAULT SETTINGS RESTORE
MENU TREE
Push and quickly release CAL button during the functioning to enter into the programming menu. Push + or - button to
navigate through the menu. Push the CAL button to enter the submenus.

LANGUAGE SELECTION

DELAY START

WHAT IS IT? The delay start is the time in minutes (0-99min) after the power on that DUAL waits for before dosing the
chemical product. During this period of time the display shows the message "Del" on the second line alternativenly with the
measure (see figure here above). During this time of delay DUAL can't dose but it is possible to enter the menu and modify
the parameters and calibrations.
Rev 1.0

DEFAULT SETTINGS

CL:
 Operation Type : Proportional
 SETPOINT: 1.20ppM
 Proportionality:1ppM
 Regulation direction: Chlorination
 Flowrate: 80% (120 imp/min)
 Alarm Time : 0unit (disabled)
Push and quickly release CAL button to enter programming and then
pressing + and – buttons select "Factory Settings Restore"
Push CAL to confirm the choice. The pump goes back to measure
restoring in memory the default settings and calibrations parameters.
Push and quickly release CAL button and then pressing + and – buttons
select the language choice "Language Selection". Push CAL to enter the
language submenu and select " English" by pressing + or - .
Push CAL to confirm the choice and ESC to go back to measuring.
DELAY START EDITING
Push and quickly release CAL button and scroll the menu using + and – buttons
till the display shows "Delay Start". Push CAL to enter the submenu and then,
by pushing + and – button, choose the value in minutes (0-99). Push CAL to
confirm and ESC to go back to measuring.
Please note that the change will take effect from the next power on of
DUAL!
Cod. 00.009.038
14