(b) Reduce the total wattage of connected electric devices within the application range.
(c) Check for blockages in the cooling air inlet and around the control unit. If any
blockages are found, remove.
(d) After checking, restart the engine.
CAUTION
• The generator AC output automatically resets when the engine is stopped and then
restarted.
• The overload indicator light may come on for a few seconds at first when using electric
devices that require a large starting current, such as a compressor or a submergible
pump. However, this is not a malfunction.
3. DC APPLICATION (option)
This usage is applicable to 12V battery charging only.
(a) Charging instruction for battery
• Disconnect the leads for the battery.
• Make the battery fluid filler cap loose fully.
• Fill distilled water to the upper limit, if the battery fluid is
low level.
• Measure the specific gravity for the battery fluid by using
the hydrometer, and calculate the charging time in
according with the table shown on right side.
• The specific gravity for the fully charged battery shall be
within 1.26 to 1.28. It is recommended to confirm every
an hour.
(b) Connect between the DC output socket and the battery
terminals using the charging leads. The leads shall be
connected making sure of the (+) and (-) polarity.
(c) The DC circuit protector is to be set to "ON" after
confirming the connection, if the protector is in "OFF"
position.
CAUTION
• Be sure the economy control switch is turned off while
charging the battery.
All manuals and user guides at all-guides.com