leaks on floors above it.
– A gas detector installed on the first floor cannot detect leaks from the
ground or second floors unless a sufficient quantity of gas reaches the
sensor.
– A closed door stops gas from reaching a detector on the other side of
the door.
Therefore the detector should be placed close to the gas appliance.
Other suggestions:
– Check that all members of the household can hear the acoustic alarms.
– It essential that the detector chosen corresponds with the type of gas
used in the house ( methane or LPG) and it is installed in a suitable
place. Otherwise it is possible that the presence of gas will not be
recognised until after the lowest explosive limit has been reached. If
both methane gas and LPG are used in your home , one detector for
each type of gas should be installed.
– The detectors are of course designed to recognise specific gases ( only
methane or LPG). Do not rely on them to detect other kinds of gas!
– On power supplying, await two minutes before testing the device.
Do not carry out any tests by opening the gas cocks.
NOTE
Products should be sold in their original packaging. When this is not the
case, the retailer or/and the installer is obliged to follow, as well as
communicate to the user, the instructions of use which are supplied with
the product . After opening the packaging, check that the appliance is
undamaged. Do not use the appliance if there is any doubt, but contact
a qualified technician. Even before unpacking, the appliance should be
handled with care and be stored in a dry place at temperatures of not
less than –5°C and not higher than +40°C.
Also note:
• Before carrying out any work on the appliance, the main supply swit-
ch shall be turned off, by cutting the power off.
• Special care should be taken in the preparation of the cable terminals
to be inserted into the appliance terminals so as to maintain sufficient
isolation distance between them.
• When tightening the terminal screws special care should be taken to
avoid overheating which could start a fire or damage the cables.
• Unless specified otherwise, this product is for use in dry, dust-free
areas. Suitable products should be used in any other conditions.
• Switches should be installed onto a board, container or fitting that
ensures the appropriate IP degree of protection for the sourrounding
conditions and their use, according to the National rules and regula-
tions in force for electrical appliances.
• Safety, efficiency and the quality marks of the product are only guaran-
teed when it is used with original plates, frames and containers.
• Install products and accessories according to CEI standards in force
for electrical systems.
• Conformity to the UNI-CEI 70028 standard and relative certification
are ONLY for the devices and NOT for Alarm Control Panels.
THIS PRODUCT SHOULD BE USED FOR ITS INTENDED PURPOSE AND
ACCORDING TO THE STANDARDS ON INSTALLATIONS AND TO
THE HEREWITH ENCLOSED TECHNICAL DESCRIPTIONS AND DATA.