❒ When wiring to additional standard
fixture only: Strip the motion sensor's
red wire and connect to the standard
light's black wire.Connect all white wires
together. Total fixture ratings must not
exceed 360 Watts (3.0 A.).
NOTE: All wiring between fixtures should be
run in accordance with the National Elec-
trical Code (U.S.) or Canadian Electrical
Code (Canada) through conduit or another
acceptable means. Contact a qualified
electrician if there is any question as
to the suitability of the system.
❒ This fixture is provided with a sensor
rated for 360 Watts. Since the fixture is
only rated 100 Watts (60 Watts for 4131
BLACK
WHITE
Wiring to Motion Light &
Standard Fixture
It is also possible to wire two motion sensing coach lights so that either unit will turn on
both lights at the same time (dual master system). It is recommended that only people with
plenty of electrical experience attempt this configuration. Please call our customer service
number (1-800-858-8501) before attempting this wiring. If the dual master wiring is not
done correctly, it can destroy both motion sensing fixtures and void your warranty.
595-5578-08
OPTIONAL WIRING
BLACK
RED
(Standard)
model and 180 Watts candelabra), 260
Watts (300 Watts for 4131 model and 180
Watts candelabra) of additional load may
be controlled by this sensor.
❒ When determining what a fixture is rated
for, do not simply look at the rating on the
lamp in the fixture. Look at the marking
which specifies the maximum lamp watt-
age for which the fixture is suitable.
❒ Once you have selected the fixtures to
be connected and determined their maxi-
mum ratings, add these ratings up. For
instance, if you have 3 fixtures rated 100
Watt, 150 Watt, and 75 Watt respectively,
you have a total load of 325 Watts.
Master
BLACK
Wiring to Control One Motion Sensing
Lantern (Slave) from Another (Master)
3
RED
BLACK
WHITE
Slave