2 - Product Dimensions and Cutout Requirements
EN
Vent hood Combinations:
It is recommended that these rangetops be installed in
conjunction with a suitable overhead vent hood.
Install a hood with at least 450 CFM.
Due to the high heat capacity of this unit, particular attention
should be paid to the hood and ductwork installation to assure
it meets local building codes.
WARNING
Air curtain or other overhead hoods, which operate
blowing a downward air flow on to a rangetop, shall not be
used in conjunction with rangetop with gas cooktop other than
when the hood and rangetop have been designed, tested
and certified by an independent test laboratory for use in
combination with each other.
Clearances to horizontal surfaces above the rangetop,
measured to the cooking surface are below. Failure to
comply may result in fire hazard.
• Installations without a hood require 48" (122) minimum
to combustibles.
• A custom hood installation with exposed horizontal
combustible surfaces must have an Auto-On feature.
• For other installations with a hood, refer to the hood
installation instructions for specific hood clearances.
CAUTION
Due to the weight and size of the rangetop and to reduce the
risk of personal injury or damage to the product:
TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION.