Induction Mode
Active Location of Utilities
Setting up the Transmitter
1. Turn the Transmitter on by pressing the
power button for two seconds.
2. Place the Transmitter over the suspected
location of the line, positioning it so that it is
along the line.
Note: Place the Transmitter at least
65 feet (20 m) away from any structure
such as building or a tower to avoid signal
interference. Avoid placing the Transmitter
over metallic manhole covers.
Note: Increasing the signal unnecessarily
may result in the signal being induced into
unwanted lines.
6
3. Press
to set the output to level
one. Increase the level if the resulting signal
strength is poor.