adaptation to different types of gas
To adapt the appliance to a gas different from that for which it was set
up (see label on both the packaging and the bottom of the appliance)
proceed as follows:
• remove the grids
• remove the covers and the spreaders
• with a 7 mm socket spanner unscrew and
remove the injectors.
• replace the injectors with those supplied
corresponding to the gas available (see burner
and injector characteristics Table)
• replace the various parts proceeding in
reverse. Remember to replace the old rating
plate with the new one (supplied).
Whenever the gas pressure used is different (or variable) from that used,
install a pressure regulator which conforms to the local regulations
in force on the input pipe.
setting the minims
The flame on the small output is regulated in the factory. When
the injectors have been replaced or there are special mains pressure
conditions, it may be necessary to regulate the minimum again. The
operations necessary to perform this operation are the following:
• light the burner
• turn the knob to the minimum
position
• take out the knob (and
gasket if there is one)
• using a suitably sized screwdriver turn the regulation screw
inside or by the side of the tap shaft until a small regular flame is
obtained
• put the knob back on and turn it quickly from the maximum
position to the minimum position, checking that the flame does
not go out
• for burners with safety valve make sure that the regulation
obtained is sufficient to maintain heating of the thermocouple. If
it is not increase the minimum.
The operations described above can easily be performed whatever
the positioning or fastening of the hob to the cabinet.
THE BURNERS REQUIRE NO REGULATION OF THE PRIMARY AIR.