instructions for installation:
electrical connection
The appliances are provided with a three-pole feeding cable and
work with alternate current and single-phase voltage indicated on
the "rating plate of the product "report at the end of the instruction
manual and on the product. The grounding conductor of the cable is
marked with the colors yellow/green.
connection of the feeding cable to the mains
Connect the feeding cable to a plug suitable for the load indicated on
the rating plate of the product. In case of a direct connection to the
mains (cable without plug), it is necessary to insert a suitable omnipolar
switch before the appliance, with minimum opening between
contacts of 3 mm (the grounding wire should not be interrupted by
the switch).
Before connecting to the mains, make sure that:
• the electrical counter, the safety valve, the feeding
line and the socket are adequate towithstand the
maximum load required (see rating plate).
• the supply system is regularly grounded,
according to the regulations in force.
• the socket or the omnipolar switch can easily be
reached after the installation of the oven
• after carrying out the connection to the mains,
check that the supplying cable does not come into
contact with parts subject to heating.
• never use reductions, shunts, adaptors which
can cause overheating or burning.
When the appliance is to be installed above a built-in oven, the two
appliances must be connected separately, to make it easier to take the
appliances out and for electrical safety.
The manufacturer is not liable for any direct or indirect damage
caused by faulty installation or connection. It is therefore
necessary that all installation and connection operations are
carried out by qualified personnel complying with the local
and general regulations in force.