Setting The Sensor - Cherubini A520012 Manual De Instrucciones

Ocultar thumbs Ver también para A520012:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

To associate the sensor to a motor, a remote control must be already memorised on the
motor. The setting sequence is the following:
At this point, do not assemble the sensor shell on the base.
• Insert the batteries provided;
• Open the awning completely (button C);
• Rotate the selector to the 0 position;
Tn: already programmed remote control
C
• Press the buttons on the remote control in this sequence: A+B and B, and then the SET
button for 2 seconds on the Mistral sensor; until the motor performs the confirmation
movement (around 2 second).
A
+
B
Tn
Note: to check proper memorisation, press the SET button briefly again: the awning should
move about half way through
its path. When the check is
completed, open the awning
once again.
The vibration detection threshold is set by choosing one of the positions on the rotating
selector, from 1 (light vibrations) to 9 (strong vibrations). The proper threshold setting for
each type of awning must be determined, through trial and error. Start out by setting a
middle value (e.g. 5) and then activate the sensor. After activation it will be possible to
perform tests to find the best threshold.
This function enables the detection of an increase in the awning inclination caused by
an accumulation of water or snow. The activation/deactivation of this function and the
load angle setting are performed during the activation of the sensor as explained below.

SETTING THE SENSOR

B
Tn
set
VIBRATION THRESHOLD
"STATIC LOAD" FUNCTION
19
set
2 sec
C
Tabla de contenido
loading

Tabla de contenido