SPC10-...-2
6

Instructions for operation

CAUTION
To avoid damage by moving into fixed stops without
cushioning:
– Carry out commissioning again after modifying the fixed
stops, adjusting the DIL switches or replacing components
– use only the permitted mass load.
Control the drive as indicated in the following table
Input/output
Output A
Output B
Input B
Input A
Change of direction is possible at any time during positioning.
The
approximately 10 to 20 strokes (adaption). Optimize the
positioning behaviour as follows:
Check the system structure; compressed air reservoir during
fluctuations in pressure; modify the supply pressure.
Modify the DIL switch setting accordingly.
If necessary, fit restrictors in the exhaust tubing of the
MPYE-5-... in order to reduce the speed.
18
Description
Supplies a 1-signal when drive is in end position A
(measuring system connection)
Supplies a 1-signal when drive is in end position B
(opposite measuring system connection)
1-Signal (min. 20 ms) sends command to move to B
(if there is an 0-signal at input A)
1-Signal (min. 20 ms) sends command to move to A
(if there is an 0-signal at input B)
positioning
behaviour
improves
automatically
after
9912a