1.
Plug the GFCI power cord to a properly grounded receptacle. It is recommended that the outlet is at least 15 feet (4.5m)
away from the pool.
2.
IMPORTANT: To start the filter pump, press the RESET button on the GFCI plug
3.
Check the return fitting on the inside of the pool for correct flow, it should feel like a solid stream of water returning
to the pool. You can use the return flow as a gauge to determine when the filter needs cleaning or replacement.
If you feel a reduction in flow, clean or replace filter.
4.
Test water and adjust as needed, read - "POOL WATER CARE" on page 12.
ALONE WILL NOT PREVENT ALGAE FROM GROWING IN POOL WATER; THIS CAN ONLY BE DONE BY
MAINTAINING PROPER CHLORINE AND pH LEVELS AT ALL TIMES!
5.
The filter cartridge may need to be cleaned and/or replaced several times at start up until the correct chlorine and pH
levels are attained. We recommend that you keep at least one spare filter cartridge on hand at all times. Filter
cartridges may be purchased at the store you purchased your pool from, or ordered from Polygroup
polygroupstore.com.
6. To turn off the filter pump, press the power button on the Pump and unplug the GFCI power cord
IMPORTANT!
Your filter pump is protected by a thermal switch. The switch senses the temperature of the filter pump. If it gets too hot, the switch
will stop the pump from running until it cools off. To restart the pump press the reset button on the GFCI when the filter pump has cooled down. This
is a safety device to prevent pump damage and prolong service life. If your pump is automatically turning off, it is because of high pool water
temperature and/or low water flow through the pump. If this happens you need to check the water flow and correct it if needed, as this filter pump
uses the water flow for cooling. You may also want to run the pump at night when the temperature is lower.
FILTER CARTRIDGE CLEANING & REPLACEMENT
1. First turn off and unplug the Power Filter Pump. Release the RF
Locking Ring
8
. Remove the RF Diverter
Fitting
6
and then plug the Return Fitting with the RF Plug
Hand tighten the SF Cap
5
3
5
3. Use both hands to twist off the Seal Top
-clockwise. Remove the Filter Cartridge
18
21
Should you encounter any problems, contact Customer Service at (888) 919-0070 from 8 AM to 5 PM Mon. thru Fri.
FILTER PUMP OPERATION
PUMP MOTOR PROTECTION
7
from the Return
onto the Suction Fitting
7
.
8
23
by turning counter
18
.
21
MST. Extended operating days and hours during peak season requirements.
22
then switch the pump on.
VERY IMPORTANT – FILTER PUMP
2. To depressurize the filter pump system, vent the filter pump by
twisting the Vent Screw
23
4. After you are finished cleaning the filter cartridge, liberally lubricate
the GASKET
order. Before restarting the filter pump, be sure to remove the RF
PLUG
and SF CAP
23
and hand tighten the RF locking ring
7
5.
The filter cartridge can be cleansed of coarse dirt and debris by pressure
washing inside and out with a garden hose, making sure to wash between
all pleats. Fine particles of dirt are more easily removed from the filter
pleats when the cartridge is dry. Therefore, after hosing the cartridge,
allow the filter to dry and CAREFULLY BRUSH the pleats to avoid
damaging the filter cartridge. DO NOT scrub the pleated surface areas.
Cleaning and scrubbing a filter too vigorously will also wear out the
cartridge much faster than if it is simply hosed off correctly.
OWNER'S MANUAL
How to use the GFCI plug
Press
"RESET"
Button
To Start
Pump
Operation
at
®
*Do not connect
to a timer device
.
22
counter-clockwise.
16
with petroleum jelly and re-assemble in reverse
19
and reinstall the Return Fitting Diverter
5
.
8
22