HYPPO
TERMINOLOGY
1: STRAIGHT CONNECTOR OF WATER INTAKE
2: 90º CONNECTOR OF WATER INTAKE
3: LOCKING CAP
4: CONDENSATION WATER DISSIPATER LID
5: BOX SIDE SCREWS
6 METAL BEARINGS
7: TERMINAL TOP
8: SIDE SCREW OF TERMINAL TOP
9: ELECTRIC CONNECTION TERMINAL
10: DRAIN PLUG
11: BLIND PLUG
12: STEAM VENT
13: ELECTRIC CIRCUIT OF FEEDING
14: AIR CONDITIONING EQUIPMENT SWITCH
15: AIR CONDIDIONING EQUIPMENT
16: CONDENSATION WATER DISSIPATER
17: 90º THREAD TOP
18: FILTER VOLUME REGULATOR
19: HOSE FOR CONDENSATE
20: PERMANENT LEVEL OF WATER
A-B AND C: CONNECTION HOLES
1: FOR YOUR OWN SAFETY
1.1: This CONDENSATION WATER DISSIPATER must be installed by a qualified professional following the
technical and safety regulations of the country where it is to be installed, and the SAFETY AND
INSTALLATION INSTRUCTIONS of the user's manual, to reduce any risk of injury and avoid any
inconvenience with the equipment guarantee.
1.2: This CONDENSATION WATER DISSIPATER has been designed to evaporate the water produced by
1Split and Compact Air Conditioning equipments. In case you need to test its performance DO NOT EVER
USE RUNNING WATER OR WELL WATER, since it could contain so many dissolved minerals that it would
dangerously raise the electric power. DISTILLED OR DEMINERALIZED WATER MUST BE USED.
1.3: The electrical wiring must have: a) a safety switch with adequate capacity, b) a residual current device
with a cut-out not exceeding 30mA.
1.4: THE CONDENSATION WATER DISSIPATER must not be fed with direct current
1.5: Before installing the CONDENSATION WATER DISSIPATER you should remove the oxide from the trays
of the Air Conditioning equipments, since the oxide can be conducted to the CONDENSATION WATER
DISSIPATER and produce electrical inconveniences
1.6: Do not install the CONDENSATION WATER DISSIPATER within reach of children and the elderly, since
its hot steam may cause serious burnings.
1.7: WHEN INSTALLING THE CONDENSATION WATER DISSIPATER, MAKE SURE THAT THE STEAM FLOWS
OUT TO THE OPEN AIR.
1.8: TO DO ANY CLEANING OR MAINTENANCE CHORE, UNPLUG THE CONDENSATION WATER DISSIPATER,
before taking off THE TERMINAL TOP (7) or the BOX LID of the CONDENSATION WATER DISSIPATER(4)
8