Figure 9: RESTRAINT
Anchor a restraint system perpendicular and away from the point
on the edge where the workplace is. There should not exist any
possibility of a fall over the edge. Therefore trim the line in the Lory
to the right length.
Figure 10: WORK ON WIND TURBINES
Use one Lory as a descender device and the other for positioning
around the blade.
Figure 11: BELAYING
Only LorySMART with dynamic ropes (EN 892) is meant for lead
climbing (do not use LorySafe). Always hold the free end of the
rope. To stop a fall, grip firmly the free end of the rope. To lower a
climber, follow similar procedures as during descent.
GENERAL INFORMATION
Regular examination:
Do not hesitate to retire the device if it shows signs of wear or after
a major fall or a major impact. They could cause internal or invisible
damage that may significantly weaken its strength. In case of
uncertainty treat the device as damaged or consult ANTHRON.
Regular periodical inspections should be carried out by an
authorised person at least once a year. For this purpose an
inspection record should be established (see the backside of
these instructions). Furthermore, we would sincerely recommend
one set of equipment is used by one person only as its history of
use is best traced and understood in this way. Before each use, it is
obligatory to check the device and verify that all its components
(handle, jamming cleat, flanges) are faultless and in good working
condition.
Packing, storage, maintenance and cleaning
Each product is packed with its INSTRUCTIONS FOR USE.
Proper maintenance and storage are imperative to ensure correct
functioning of the product (as well as all your equipment) and thus
your safety.
Clean the product with a brush under running cold water of
domestic supply. If the stains persist, clean it in warm water
(maximum 30 °C) with ordinary soap. Then rinse thoroughly, wipe
it with a towel and dry naturally in a shaded ventilated place away
from sources of heat.
If needed, lube sparingly the moving joints of the cam and handle
with silicon based oil.
Temperatures
While it is permissible to use this product within the temperature
range from -20 °C to +60 °C, it is advisable to stock it in a dry place
at room temperature.
Lifetime
It is impossible to indicate the exact lifetime of this product for it
depends on the frequency and mode of application, on the
environment where it is used (marine, cave, corrosive
atmosphere) and on mechanical wear or damage. Provided its
correct use (in accordance with these instructions), the lifetime of
the product on average use is expected to be 7 years.
Guarantee and its limitations
This product is guaranteed for 3 years from purchase against any
faults in materials or manufacture. The guarantee does not apply
in cases of misuse, normal wear and tear, unauthorised
modifications or alterations, improper use, improper maintenance,
accidents, negligence, damage or if the product is used for a
purpose it was not designed for. If you discover a defect, you
should return the product to the reseller you purchased the product
from or directly to ANTHRON.
ANTHRON is not responsible for the consequences of direct,
indirect, accidental or any other type of damage resulting
from the use of its products.