In the same way, adjust the shutdown times. The program
is confi rmed by pressing the MENU button when 'Save
OK' appears on the display.
When confi rming the 'Weekly program' the day to which
the program is to apply must be selected:
1 Mon; 2 Tues; 3 Wed; 4 Thurs; 5 Fri; 6 Sat; 7 Sun
Once you have chosen the day by scrolling through them
with the + and – keys, confi rm by pressing MENU and
proceed with the settings of the programs in the same way
as for the 'Daily program', selecting whether or not to
enable a program for each day of the week and choosing
the number and times of interventions.
Should you make a mistake whilst setting the programs
you can exit without saving by pressing the 0/1 key.
Note on fl ame variability
The fl ame may vary depending on the type of pellets
used, in addition to normal variability of the solid fuel
fl ame and regular cleaning of the combustion chamber
carried out automatically by the stove.
N.B. The automatic cleaning process performed by the
stove does not replace the need for the user to vacuum the
stove when cold, prior to ignition).
Pellet reserve warning
Stoves are equipped with an electronic pellet detection
system.
The detection system is integrated into the electronic
control board, allowing the stove to monitor how many
kilos of pellets are left. This verifi cation is implemented
at any point whilst the stove is in operation mode.
For correct system operation, it is important that the
following procedure is adhered with during the fi rst
ignition (that must be implemented by the DEALER).
Before starting to use the pellet detection system, you
must load and consume a full sack of pellets. This
allows for a brief running-in of the loading system.
Hence, load 15 kg of pellets.
Then press the 'reserve' button once, thereby storing
the data into the memory that 15 kg have been loaded.
From now on the display will show the remaining pellets
as they decrease in kg (15...14...13).
Each time pellets are reloaded you must enter the quantity.
E.g. when loading 15 kg, simply press the 'pellet
load' button to enter this into the memory. For other
quantities, or in the event of an error, you can specify
the quantity using the pellet reserve menu as follows:.
Press the MENU button for 2 seconds to view the SETTINGS.
Press + or – consecutively to view T. Max E.
Confi rm by pressing MENU and the remaining quantity
of pellets will be displayed + that being loaded
(default is 15 and can be changed using the +/- keys).
Should the hopper run out of pellets, the stove will
block and 'Stop/Flame' will appear (see page 35).
Note: Every now and again remember to reset the "pellet
reserve warning" for it to function in a more reliable
manner.
For any clarifi cation please contact the authorised
DEALER who performed the fi rst 1st ignition.