Troubleshooting - GYS BATIUM 7/12 Manual De Instrucciones

Ocultar thumbs Ver también para BATIUM 7/12:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
Translation of the original instructions

TROUBLESHOOTING

ANOMALIES
The charge indicator 1 is swit-
ched off. The battery voltage
1
indicators blink alternatively
after 1 minute of charging.
The battery capacity indica-
2
tors flash alternatively.
The battery is connected.
The charge indicator 1 does
not switch on. The battery
3
voltage indicators and bat-
tery capacity indicators are
switched on.
The indicator light «SOS
Recovery» (Batium 15.12
4
et 15.24) flashes after one
minute of charge.
SOS RECOVERY (Batium
15.12 / 15.24) : after 24
5
hours, the charge and end of
charge indicators are swit-
ched off.
Forced charge : After pressing
the battery voltage button
6
during 5 seconds to start the
forced charge, the indicator
does not switch on.
When connecting to the
7
mains, no indicator switches
on
12
BATIUM 7/12 • 7/24 • 15/12 • 15/24
CAUSES
The selected voltage does not
match the battery voltage.
The battery cannot be recovered.
The battery is in short circuit or
damaged
A power consumer has been left
on accidentally (e.g. lights).
The charger is used as a power
supply to compensate for the use
of power consumers that are drag-
ging the battery's energy.
The battery capacity (Ah) is higher
than the charger's
The battery voltage does not rise,
the battery is damaged.
Polarities + and – are reversed
Bad clamp connections.
The battery is deeply discharged.
The fuse is melted.
The battery has suffered a deep
discharge over a long period, with
a start in sulfation. . The charge
continues but it is recommended to
switch to « SOS recovery ».
Battery cannot be recovered
Battery voltage < 0.5 V (± 0.3)
SOLUTIONS
- Disconnect the machine from the
mains while keeping the clamps connec-
ted to the battery.
- Choose the right voltage
- Then reconnect the BATIUM to the
battery.
Change the battery.
Change the battery.
Switch off the power consumer and
continue/restart the charge
Charger behaves normally but incorrect
use. The indicator that signals the end
of the charge cannot switch on.
The charging time will be abnormally
long. If possible, use a more powerful
charger
Choose the capacity indicated on your
battery.
Change the battery.
Put the red clamp at the + the black
clamp at the -
Clean the terminals and reconnect the
clamps.
Use the « forced charge » mode (see
the procedure on the previous page)
Disconnect the machine from the mains.
Remove the clamps from the battery.
Replace the fuse with regard to its size
(15 A for a Batium 7-12 7-24 or 30 A for
a Batium 15-12 and 15-24).
Disconnect the machine from the mains,
then the clamps. Activate the « SOS
Recovery » mode, see the previous
page.
Battery to be replaced
Battery to be replaced
Disconnect the Batium from the mains
during 10 sec., then reconnect it.
EN
Tabla de contenido
loading

Este manual también es adecuado para:

Batium 15/12Batium 7/24Batium 15/ 24

Tabla de contenido