Mobilfix On Steel Structures (Hexagonal Nut) - SKYLOTEC Mobilfix AP-018 Instrucciones De Montaje Y Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65

5.1.3 MOBILFIX on steel structures (hexagonal nut):

For installation on steel or steel structure
The substructure should enclose the Mobilfix sleeve by at least 40mm in the first part from the disc and must not
protrude more than 10 mm from the disc to the substructure. Threading in a steel structure is possible. The area
where the attachment point will be mounted must safely absorb the static forces of 14 kN. The static load capacity
of this area must be demonstrated. The screw connection must be secured with liquid screw locking against
unintentional loosening.
MAT-MA-0007 MOBILFIX
:
Stand: 08/11/2016
Seite 7 von 16