Electrical Connections - DITEC Silver 1B Manual Para La Instalacion Y La Manutencion

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

4. ELECTRICAL CONNECTIONS

Drill a hole in cover [9] in correspondence with [E] (facing downwards) to route the cable (see Fig. 3).
Attention: Cable must be secured by means of a cable fitting (not supplied).
The SILVER 1B/40B geared motors can be connected to electric panels D1, D2, LOGIC A21, LOGIC A22.
Connect the geared motors SILVER 1B / 40B as shown in fig. 8 (1 wing) other in fig. 9 (2 wings).
5. MAINTENANCE PROGRAM (each 6 month)
Power off (230 V~ mains and batteries, if installed):
-
Clean and lubricate the pivot pins.
-
Check that fastening points are properly tightened.
Power on (230 V mains and batteries, if installed):
-
Check the power adjustments.
-
Check the operation of all command and safety functions (photocells).
-
Check the good operation of the release.
ATTENTION: For spare parts, see the spares price list.
GENERAL SAFETY PRECAUTIONS
The following precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully
as they contain important indications for the safe installation, use and maintenace. These instruction must be kept and forwarded
to all possible future user of the system. This product must be used only for that which it has been expressely designed. Any other use
ON
OFF
In particular regular checks are recommended in order to verify that the safety devices are operating correctly.
All installation, maintenance and repair work must be documented and made available to the user.
DITEC S.p.A.
Via Mons. Banfi, 3
21042 Caronno P.lla (VA) Italy
Tel.+39 02 963911 - Fax +39 02 9650314
www.ditec.it
TEAR OFF AND DELIVER TO USER
Operating instruction SILVER 1B / 40B
Electromechanical automatic system for swing gates.
Keep remote control or any other control devices out of the reach of children, in order to avoid
possible involuntary activation of the motorised door or gate. In case of breack down or malfunc-
tioning of the product, disconnect from mains, do not attempt to repair or intervene directly and
contact only qualified personnel. Failure to comply with the above may create a situation of
danger.
All cleaning, maintenance or repair work must be carried out by qualified personnel.
In order to guarantee that the system works efficiently and correctly it is indispensable to comply
with the manufacturer's indications thus having the periodic maintenance of the motorised door or
gate carried out by qualified personnel.
ISO 9001 - Cert. n° 0957/1
RELEASE INSTRUCTION
In case of faulty operation or power failure, insert and
rotate the key clockwise. Unlock the electric lock, if
mounted. Manually slide the gate open.
To relock the wings, turn the key anticlockwise.
Attention: Lock and release operations must be
performed with motor not running.
is to be considered improper and therefore danger-
ous.
The manufacturer cannot be held responsible for
possible damage caused by improper, erroneous or
unresonable use. Avoid operating in the proximity of
the hinges or moving mechanical parts. Do not enter
the field of action of the motorised door or gate while
in motion. Do not obstruct the motion of the motorised
door or gate as this may cause a situation of danger.
Do not allow children to play or stay within the field
of action of the motorised door or gate.
Installer:
Tabla de contenido
loading

Este manual también es adecuado para:

Silver 40b

Tabla de contenido