4. BATTERY
EWKB5 does NOT feature a built-in battery charging unit, therefore only
1,5V Lithium AA type (non-rechargeable) batteries can be used. The
batteries are used only in case of a main power failure!
BATTERY REPLACEMENT
1. Activate Service mode by accessing the settings menu (Master code required) or
using alternative methods, such as SMS text message.
2. Open EWKB5 enclosure.
3. Remove the old batteries from the battery slots.
4. Insert the new batteries based on the battery slot positive/negative terminals
indicated on the battery slots of EWKB5.
• Only 1,5V Lithium AA type FR6 (IEC) / 15LF (ANSI/NEDA) batteries can be
used. Install only new, high quality and unexpired batteries. Do not mix the
old batteries with the new ones.
• All batteries must be removed if the device is not in use.
• In order to avoid fire or explosion hazards, the system must be used only with
approved battery. Special care must be taken when connecting positive and
negative battery terminals. Dispose old batteries only into special collection
sites. Do not charge, disassemble, heat or incinerate old batteries.
• The battery status can be monitored in real-time on EWKB5 screen or by
using ELDES configuration software.
• The system sends an SMS text message to the listed user phone number as
soon as the battery level runs below 5%.
5. RESTORING DEFAULT PARAMETERS & UPDATING FIRMWARE
In order to restore default parameters, EWKB5 must be powered on either by the main
power supply or by battery power.
RESTORING DEFAULT PARAMETERS
1. Open EWKB5 enclosure.
2. Press and hold the RESET button for 10 sec.
3. Watch the red indicator flash several times.
4. Release the RESET button.
5. Parameters restored to default values.
ELDES WIRELESS TOUCHPAD EWKB5 V1.1
EN
7