Temperature Adjustment - UPC CD Serie Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1. Remove the handle on the thermostat control. The method will differ
depending on the handle type.
2. Please note: Some handles have an integral stop and some handles have a
separate brass stop ring.
3. If a Brass Stop Ring is in place, please remove it. Turn the shower flow
control fully on.
4. If the shower is too cold then turn the cartridge spline anti-clockwise. If
the handle is too hot then turn the spline clockwise. Let the water
temperature stabilise after every adjustment. The max temperature
should be no more than 47°C (116.60°F).
5. When the temperature is correct, turn the flow control off. Do not move
the temperature spline again until after the handle is secured in place. The
max temperature is now set and any movement of the spline will alter the
temperature.
6. The handle can now be put back in place. When the handle is being
placed over the spline, please ensure that the handle Stop Lug is against
the cartridge Stop Lug preventing the handle from being turned any
further anti clockwise. This prevents the shower valve from reaching a
temperature that is higher than the set point.
Depending on your handle type the temperature will be limited by a
handle with an in build stop lug or by a separate Brass Stop Ring. Please
see the diagrams below.
7. The handle can now be fixed in place. The shower should have a safe
maximum showering temperature.

7. TEMPERATURE ADJUSTMENT