Tabla de contenido
Alarm Low (LOW)
If the set temperature is reached during
a scan, "LOW",
, and temperature
will flash
Log (LOG)
Use the arrow keys to select the data
location (1-20). Pull the trigger to scan
the temperature. Press the LOG key to
save the reading to the selected data
location.
Emissivity (E)
Set the emissivity of the surface being
scanned (0.95 is the default). During a
temperature scan, the set emissivity
value is displayed. Refer to an
Emissivity Table for proper surface
settings.
Laser ON/OFF (
)
Turns the laser pointer on and off while
the IR continues to take readings.
°F / °C (F)
Determine if temperature readings are
displayed in Fahrenheit or Celsius.
Alarm ON, OFF, MUTE
Use the Alarm ON/OFF button to turn
the alarm on and off, and mute the
alarm after it sounds. The bell icon will
go off. The temperature reading will
continue to flash as long as it is outside
the preset range.
Fuel Gauge
The battery icon displays the remaining battery life. Charge the
battery according to the battery and charger manual.
14
ENGLISH
BATTERIES
New battery packs reach full loading capacity after 4 - 5
chargings and dischargings. Battery packs which have not
been used for some time should be recharged before use.
Temperatures in excess of 50°C (122°F) reduce the
performance of the battery pack. Avoid extended exposure to
heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept clean.
To obtain the longest possible battery life remove the battery
pack from the charger once it is fully charged.
For battery pack storage longer than 30 days:
Store the battery pack where the temperature is below 27°C
and away from moisture
Store the battery packs in a 30% - 50% charged condition
Every six months of storage, charge the pack as normal.
MAINTENANCE
Clean the laser windows with a soft, moist cloth to keep them
clean and clear. Remove battery before cleaning.
Warning!
To reduce the risk of personal injury and damage, never
immerse your tool in liquid or allow a liquid to fow inside it.
Clean dust and debris from tool. Keep tool handles clean, dry
and free of oil or grease. Use only mild soap and a damp cloth
to clean the tool since certain cleaning agents and solvents are
harmful to plastics and other insulated parts. Never use
flammable or combustible solvents around tools
Use only Milwaukee accessories and Milwaukee spare parts.
Should components need to be replaced which have not been
described, please contact one of our Milwaukee service agents
(see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the Article No. as well as the machine type printed on the
label and order the drawing at your local service agents or
directly at: Milwaukee Electric Tool, Max-Eyth-Straße 10,
D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before
starting the machine.
Remove the battery pack before starting any
work on the machine.
Do not stare into beam.
2
This product corresponds to the laser class 2 in
accordance with IEC60825-1.
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2002/96/EC on waste
electrical and electronic equipment and its
implementation in accordance with national law,
electric tools that have reached the end of their
life must be collected separately and returned to
an environmentally compatible recycling facility.
TECHNISCHE DATEN
Laser Thermometer C12 LTGH
Laser Klasse ............................................................................... 2
Maximale Leistung.................................................................... <1 mW
Laserwellenlänge........................................................... 630 - 670 nm
Infrarot Temperatur Bereich ........................................-30°C - 800 °C
Infrarot Messgenauigkeit
-30°C - 0°C ......................................................................... ±1,5 °C +0.1/1°C
0°C - 120°C ....................................................................... ±1,0 °C +0.02/1°C
120°C - 380°C ................................................................... ±1,5 °C oder 1.5% der Anzeige, der größere Wert zählt
380°C - 800°C ................................................................... ±2,0 °C oder 2% der Anzeige, der größere Wert zählt
bei einer Umgebungstemperatur von 23°C to 25°C
Min. Messdinstanz ..................................................... 50 mm < 50 °C, 100 mm > 50 °C
Auflösung Anzeigen ................................................................. 0,1 °C (Primär- und Sekundäranzeige)
Temperaturbereich bei Kontaktmessung ....................-40°C - 550 °C
Eingangsgenauigkeit bei Kontaktmessung........................... ± 1,1 °C
Auflösung Temperaturanzeige ................................................ 0,1 °C (Primär- und Sekundäranzeige)
K-Type Sonde Temperaturbereich ..............................-40°C - 260 °C
K-Type Sonde Eingangsgenauigkeit ....................... < 400°C ±2,5 °C
Emmisionsgrad ...............................................Voreinstellung 0.95 (kann manuell verändert werden)
RH Anzeige.....................................................................10% - 90 %
RH Genauigkeit ........................................................................ ±5 %
Reaktionszeit ........................................................................ <500 msec
Spektralbereich.................................................................... 8 - 14 µm
Verhältnis Abstand zu Messbereich...................................40 zu 1
Wiederholgenauigkeit ............................................................ ±0,5 % oder ±1°C(der größere Wert zählt)
Arbeitstemperatur ............................................................ 0°C - 50 °C
Lagerungstemperatur ...................................................-20°C - 60 °C ohne Wechsleakku
Relative Luftfeuchtigkeit ................................................... 10 - 90 % RH nicht kondensierend bei <30°C Umgebungstemperatur
Spannung Wechselakku ........................................................... 12 V
Akkulaufzeit ........................................................................... > 12 h mit allen Funktionen
Gewicht nach EPTA-Prozedur 01/2003 .................................. 500 g
WARNUNG! Lesen Sie alle Sicherheitshinweise und
Anweisungen, auch die in der beiliegenden Broschüre.
Versäumnisse bei der Einhaltung der Sicherheitshinweise und
Anweisungen können elektrischen Schlag, Brand und/oder
schwere Verletzungen verursachen.
Bewahren Sie alle Sicherheitshinweise und Anweisungen
für die Zukunft auf.
SPEZIELLE SICHERHEITSHINWEISE
Nicht in den Laserstrahl blicken und nicht auf andere Personen
richten.
Nicht mit optischen Hilfsmitteln (Fernglas, Fernrohr) in den
Laser blicken.
Den Laser nicht auf reflektierende Flächen richten.
Nicht der Laserstrahlung aussetzten. Der Laser kann
gefährliche Strahlung aussenden.
Nicht in gefährlicher Umgebungen benutzen. Nicht bei Regen,
Schnee, an feuchten oder nassen Orten verwenden. Nicht in
explosionsgefährdeten Bereichen (Rauch, Staub oder
entflammbare Materialien) benutzen, da beim Einsetzen oder
Entnehmen des Wechselackus Funken erzeugt werden
können. Dies kann Feuer verursachen.
Vor dem Einsetzen oder Entfernen des Akkus alle Kabel und
Leitungen vom zu prüfenden Objekt trennen und Gerät
ausschalten.
Verbrauchte Wechselakkus nicht ins Feuer oder in den
Hausmüll werfen. Milwaukee bietet eine umweltgerechte
Alt-Wechselakku-Entsorgung an; bitte fragen Sie Ihren
Fachhändler.
Wechselakkus nicht zusammen mit Metallgegenständen
aufbewahren (Kurzschlussgefahr).
Wechselakkus des Systems C12 nur mit Ladegeräten des
Systems C12 laden. Keine Akkus aus anderen Systemen
laden.
Unter extremer Belastung oder extremer Temperatur kann aus
beschädigten Wechselakkus Batterieflüssigkeit auslaufen. Bei
Berührung mit Batterieflüssigkeit sofort mit Wasser und Seife
abwaschen. Bei Augenkontakt sofort mindestens 10 Minuten
gründlich spülen und unverzüglich einen Arzt aufsuchen.
Dieses Gerät ist nicht dafür bestimmt, durch Personen
(einschließlich Kinder) mit eingeschränkten physischen,
sensorischen oder geistigen Fähigkeiten oder mangels
Erfahrung und/oder mangels Wissen benutzt zu werden, es sei
denn, sie werden durch eine für ihre Sicherheit zuständige
Person beaufsichtigt oder erhielten von ihr Anweisungen, wie
das Gerät zu benutzen ist.
Kinder sollten beaufsichtigt werden, um sicherzustellen, dass
sie nicht mit dem Gerät spielen.
BESTIMMUNGSGEMÄßE VERWENDUNG
Das Laserthermometer ist geeignet zur berührungsfreien
Temperaturmessung oder zur Temperaturmessung mit einer
K-Type Temperatursonde.
Dieses Gerät darf nur wie angegeben bestimmungsgemäß
verwendet werden.
DISPLAY
Ladezustand Akku
Emissionsgrad
Laser aktiv
Emissionsgrad aktiv
Alarm ein
Wert halten
C° oder F° Anzeige
Primäranzeige
Luftfeuchtigkeit
Sekundäranzeige
Schalterarretierung aktiv