Connecting the power supply
How to proceed:
 E
Unit version with power plug:
 Push the coupling of the power cable onto the unit plug.
 F
Unit version with power cable:
 Connect the unit to the power supply.
– Work on the power supply may only be carried out by a qualified electrician.
– Adhere to the pin assignment specified on the power cable label.
– Only use wires with wire end ferrules for connection.
Connecting the unit
The correct fastening of the plug connector is important for a secure connection and an interference-free EGC network.
An EGC connection cable is necessary for connection.
 The EGC connection cable is available as an accessory in the lengths 10 m (47040), 5 m (47039) and 2.5 m (47038).
How to proceed:
 G, H
1. Remove the terminal resistor from the unit.
2. Fit the plug connector and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
3. Remove the protection cap from EGC-OUT of the last unit in the EGC network, fit the terminal resistor and secure it
with the two screws (max. 2.0 Nm).
– No EGC connection cable is connected to EGC-OUT on the last unit in the EGC network. The terminal resistor
has to be fitted to this EGC-OUT so that the EGC network is correctly terminated?.
– The terminal resistor is included in the delivery scope of the InScenio FM-Master WLAN EGC.
N O T E
For further information regarding the operation and integration into the EGC system, please refer to the instructions for
use of the FM Master WLAN EGC at http://www.oase-livingwater.com/egc-start.
Connect the units to the power supply distributor
How to proceed:
1. Choose a suitable socket (see fig. above) and insert the unit power plug into the socket.
– Check that your OASE unit may be connected to this socket. For this purpose, consult the instructions of use of
the unit you wish to connect.
– The following applies: Units powered via a transformer may not be connected to a socket with dimmer function.
 I
2. Fit the protection hood.
1 Socket 1, switchable (max. 10 A / 2000 W)
2 Socket 2, switchable (max. 10 A / 2000 W)
3 Socket 3, switchable (max. 10 A / 2000 W)
4 Socket 4, switchable and dimmable (40 W ... 320 W)
Note: Ensure that the total output of 16 A / 3600 W is not exceeded!
- EN -