Electric Connections - PSA Zodiac Heat Line Manual De Instalación Y De Uso

Intercambiador de calor aqua-aqua
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
House heating
circulation pump
House
heating
Aquastat
Caution! Connections of primary circuit shall be
realised before any valve or pump.
Installation advised:
X = Y: minimum 15 to 20 cm
Note 1: advised fitting to retain water permanently in the exchanger body.
Note 2: advised fitting to avoid aggressive chlorine feedback into the heater when the filtering is stopped

4.2 Electric connections

• The single-phase electrical supply (230V-50Hz) of the exchanger must come from a protection and
switching device (not supplied) complying with the standards and regulations in force in the country
where it is installed (in France, refer to standard NF C 15100).
• use the supply cable delivered with the appliance: 2 poles + Earth 10/16 A in 3G1 (section 1 mm²).
Do not admit any long extension or multisocket connection.
Remark: Plan for a socket to connect the supply cable delivered with the appliance.
• Electrical protection: this current socket must have a 5 A fuse switch with, upstream, a 30 mA
differential circuit breaker (calibre > than 5 A), or an independent 30 mA circuit breaker (calibre 5 A)
upstream.
Note:
• The acceptable voltage variation during operation is ± 10%,
• electric cables shall be fixed.
HYDRAULIC CONNECTIONS
TO RADIATORS
Valves
Pressure valve
Expansion vessel
Gas or Fuel-oil boiler
X
Heatline in case
Connection Heatline in case exchanger
Electric box
230V-1N-50Hz-~-
Circulating pump
E
Pump
Filter
Y
Water treatment
Filtration electric box
Single-phase Main supply 230Vac + neutral + Earth
4
Pool water filtration circuit
Primary circuit
House heating circuit
Automatic air bleed
Check valve
S
Water treatment
Heat Line in case
E = From pool
S = To pool
Tabla de contenido
loading

Tabla de contenido