1.4

High pressure applications

Selection
DANGER
When selecting sensors, ensure that their overload pressure
will not be exceeded.
The "diesel effect" caused by entrapped air can result in pres-
sure spikes that far exceed the maximum pressure. The operat-
ing pressure of the sensors should be higher than the operating
pressure of the system to be measured.
Installation
NOTICE
Please follow the instructions and observe the correct tighten-
ing torques for fittings and adapters.
Please observe the highest pressures as specified in the cata-
logues for hydraulic fittings or hydraulic hoses.