3.7.6
Lista de códigos de error que se muestran en la pantalla
Code F
Short description
F01
hydraulic oil sensor
F02
material flow sensor
F03
brake pressure sensor
F04
engine cooling sensor
F05
engine oil level sensor
F06
engine air filter sensor
F07
drive pump sensor
F08
Engine CAN BUS error
F11
joystick
F12
speed potentiometer
F13
travel mode switch
F14
material flow mode switch
F15
material flow direction switch
F16
screed height switch
F19
screed vibration switch
F21
horn button
F22
engine start switch
F23
deadman button
F24
extension left in switch
F25
extension left out switch
F26
extension right in switch
F27
extension right out switch
F28
joystick forward switch
F29
joystick reverse switch
F30
joystick neutral switch
F31
drive pump forward
F32
drive pump reverse
F33
drive pump safety
F34
brake release output
F35
brake release safety
F36
material flow valve forward
F37
material flow valve reverse
F38
material flow safety
F39
floating valve
F40
floating safety
The texts are given only in the original language version or as a translation of the original into the English language version.
The texts are given only in the original language version or as a translation of the original into the English language version.
F80W
Causes and troubleshooting
short circuit to ground detected – check wiring (X41, RD 141, WH 227)
short circuit to ground detected – check wiring (X43, RD 143, WH 229)
short circuit to ground detected – check wiring (X42, RD 142, WH 228)
short circuit to battery detected – check wiring (X18:5, X35)
short circuit to battery detected – check wiring (X17:4)
short circuit to battery detected – check wiring (X18:3)
short circuit to ground or battery or no connection detected – check wiring (X38,
WH 214, WH 217, WH 222)
Check CAN communication (A9:47,A9:48, X9:3, X9:4, X50, X51, X52, X53, X55,
X34:62, X34:63, A2:162, A2:163)
most frequent cause: joystick not calibrated; error param 1 to 6: redundancy failu-
re; error param 7: not calibrated; error param 8: error on main channel; error param
9: error on redundant channel (X36)
most frequent cause: error on main channel; error param 1 to 6: redundancy failure;
error param 8: error on main channel; error param 9: error on redundant channel
short circuit to ground detected – check wiring (X53, RD 153, WH 243)
short circuit to ground detected – check wiring (X52, RD 152, WH 242)
short circuit to ground detected – check wiring (X51, RD 151, WH 240, WH 241)
short circuit to ground detected – check wiring (X48, RD 148, WH 236, WH 237)
short circuit to ground detected – check wiring (X49, RD 149, WH 238)
short circuit to ground detected – check wiring (X45, RD 145, WH 231)
short circuit to ground detected – check wiring (137)
short circuit to ground detected – check wiring (X44, RD 144, WH 230)
short circuit to ground detected – check wiring (X46, RD 146, WH 233)
short circuit to ground detected – check wiring (X46, RD 146, WH 232)
short circuit to ground detected – check wiring (X47, RD 147, WH 234)
short circuit to ground detected – check wiring (X47, RD 147, WH 235)
short circuit to ground detected – check wiring (X36)
short circuit to ground detected – check wiring (X36)
short circuit to ground detected – check wiring (X36)
short circuit to ground or battery or no connection detected – check wiring and
coil (X 65, Y12, WH 263, WH 265, WH 266)
short circuit to ground or battery or no connection detected – check wiring and
coil (X66, Y13, WH 264, WH 266)
short circuit to ground or battery or no connection detected – check wiring and
coil (X65, X66, Y12, Y13, WH 263, WH 264, WH 265, WH 266)
short circuit to ground or battery or no connection detected – check wiring and
coil (X60, Y7, WH 256, WH 257)
short circuit to ground or battery or no connection detected – check wiring and
coil (X60, Y7, WH 256, WH 257)
short circuit to ground or battery or no connection detected – check wiring and
coil (X54, Y1, WH 244, WH 246, WH 247)
short circuit to ground or battery or no connection detected – check wiring and
coil (X55, Y2, WH 245, WH 247)
short circuit to ground or battery or no connection detected – check wiring and
coil (X54, X55, Y1, Y2, WH 244, WH 245, WH 246, WH 247)
short circuit to ground or battery or no connection detected – check wiring and
coil (X61, Y8, WH 258, WH 259)
short circuit to ground or battery or no connection detected – check wiring and
coil (X61, Y8, WH 258, WH 259)
MANUAL DE MANTENIMIENTO