Eliminación De Fallos Del Sistema Eléctrico; Eliminación De Fallos De La Calefacción Del Listón Al Encenderse La Luz De Control De Los Errores Activos Y Visualización Del Código De Error En La Pantalla - Fayat DYNAPAC F80W Manual De Instrucciones

Tabla de contenido
3.7
Eliminación de fallos
Fault
Incorrect response of the servo-device
3.7.4
Eliminación de fallos del sistema eléctrico
Fault
Electrical system not operating
Incorrect starter function
The battery charging indicator lamp does
not turn off after engine is started.
During engine operation, the battery char-
ging indicator lamp glows
3.7.5
Eliminación de fallos de la calefacción del listón al encenderse la luz de control de los errores
activos y visualización del código de error en la pantalla
Fault
The active error indicator lamp and an
error code light up on the display imme-
diately after the screed heating is switched
on.
The active error indicator lamp and an
error code light up on the display during
screed heating
176
Possible causes
Leak of the linear hydraulic motor
Leak of the drive pump or the opera-
ting pump
Insufficient pump revs
Incorrectly calibrated valves
Possible causes
Connections or clamps on battery loo-
se or corroded
Discharged battery
The battery disconnecter is turned off
A faulty fuse
Loose or corroded battery connecti-
ons and clamps
Insufficient power supply from battery •
Incorrect engine oil viscosity
Idle engine revolutions are too low
Battery not operating correctly
Alternator not operating correctly
Alternator not operating correctly
Possible causes
Closed gas supply
No gas
Safety valve
No gas, little gas in the bottle
Flame ignition system fault
Corrective action
Have the linear hydraulic motor re-
paired
Have the drive or operating pumps
repaired
Increase speed of the engine
Have the valves repaired
Corrective action
Have connections cleaned, lubricated
and tightened
Check the battery and charge it
Turn on the battery disconnecter
Identify the cause and replace the fuse
Have the battery connections and
clamps cleaned and tightened
Have the open circuit voltage of the
battery checked.
Have the oil replaced with a  manu-
facturer-approved oil
Have the idle revolutions of the engine
increased
Have the open circuit voltage of the
battery checked
Have the alternator repaired
Have maintenance and repairs perfor-
med on the alternator
Corrective action
Open gas supply
Replace the gas bottle
Safety valve test and pressure check.
Replace the gas bottle
Have the screed gas-heating system
repaired.
F80W
Tabla de contenido
loading

Tabla de contenido