Compressor must be connected to a power supply socket protected by a suitable
magneto-thermic switch.
The tabs show the absorption data for each type of compressor:
The compressor power supply cable or its eventual extensions must havean adeguate
wire section, proportioned to its lenght.
Thefollowing table shows the wires section data for each type of compressor in relation
to the lenght:
Tank filling time from 0 to 7 bar ( test temperature 20°C)
-
230V/50Hz: 26 sec
-
115V/60Hz: -- sec
Check the compressor as follows:
1.Empty the compressor air tank
2.Close the compressor outlet on the tank and check that the drain cap is closed
3.Start the compressor and check the time elapsing between starting and automatic
switching off
4. Check that there are no leaks on connections.
5. check max. pressure= 7 bar/100 Psi
I
WARNING!
Motor type
230 V
50 Hz
2,17A
To 3 mt.
230 V
115 V
50 Hz
60 Hz
1 mm
1,5 mm
2
2

2.3 FILLING UP

2.4 CHECK OF FILLING TIME

115 V
60 Hz
5,2 A
From 3
to 20 mt.
230 V
115 V
50 Hz
60 Hz
1,5 mm
2,5 mm
2
2
GB
13