Before you begin - Read these instructions completely and carefully.
IMPORTANT – OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Note to Installer – Be sure to leave these instructions with the Consumer.
Note to Consumer – Keep these instructions with your Owner's Manual for future reference.
For further details, refer to the GE Architects & Engineers Design Data Manual for Zonelines. To obtain a copy of that
manual, call the GE Answer Center
NOTES:
• Handle the case carefully.
• The cardboard stiffener inside the case, and the rear
protective panel must remain in place until the chassis
is installed to assure case rigidity and squareness.
• If a sub-base is to be used, it may be desirable to
assemble it to the case before securing the case
in the wall.
CRITICAL DIMENSIONS
Outside wall
"C"
NOTE:
Care should be taken in location of electrical supply
entry in relationship to wall sleeve to ensure access
to power once the unit is installed.
Printed in the United States
at 800.626.2000 or visit us at www.Zoneline.com.
®
Ceiling
"A"
"B"
Roomside
"D"
Finished floor or top of carpet
Installation Instructions
for your new
RAB71B Standard
or RAB7116B &
RAB7124B
Extended Room Air Conditioner Case
for AZ Series Zoneline Models Only
CASE LOCATION
Case must be located on an outside wall for proper
operation. As a general rule the air conditioner
should be centrally located in an outside wall to
ensure proper distribution of conditioned air. It should
be located in a portion of the wall where there is no
electrical wiring or plumbing, and where there are no
obstructions immediately inside or outside.
RECOMMENDED
DIMENSIONS
INSTALLATION CLEARANCE
A
B
Projection of case into room from finished
wall - 1/4 min. (no sub-base)
2
8
If more than 6 of the case projects
into the room, a sub-base or other
support is recommended.
C
D
Height above finished floor or
0 min. without sub-base
min./5" max. with sub-base
E
Left/Right side of case to adjacent
INSTALL CASE LEVEL IN ALL DIRECTIONS
"E"
1
min. when sub-base is used.
min.
Top of case
31-30779-1
min.
min.
Outside wall
"E"
02-16 GE
loading

Resumen de contenidos para GE RAB71B

  • Página 9 Para mayores detalles, consulte el Manual de información de diseño para arquitectos e ingenieros de GE para Zonelines. Para obtener una copia de ese manual, llame al Centro de Respuestas GE al 800.626.2000 o visítenos en www.Zoneline.com. ® NOTAS: UBICACIÓN DE LA CAJA...
  • Página 10: Preparación De La Pared

    DIMENSIONES DE ABERTURAS MÍNIMAS TERMINADAS* DIMENSIONES DE LA CAJA Altura Ancho Altura Ancho Profundidad RAB71B RAB7116B RAB7124B * Las dimensiones pueden tener que incrementarse para adecuarse a situaciones únicas en el campo si se utilizan ángulos de la caja.
  • Página 11 PASO 3 PASO 4 Instalación de la caja en la abertura de la pared Resistencia a la intemperie 1. Coloque la caja dentro de la pared. Consulte Deben sellarse con calafateo o un material la tabla de la página 1 sobre proyección del lado equivalente resistente a la intemperie los espacios de la habitación.
  • Página 12 El código no permite enchufar una unidad de 265V METAL tipo “A” directamente en un tomacorriente expuesto montado en el edificio. Ver el Manual del propietario sobre cómo conectar el suministro eléctrico. Las especificaciones pueden sufrir cambios sin previo aviso Un producto de calidad de GE Appliances...

Este manual también es adecuado para:

Rab7116bRab7124b