Electrical Characteristics; Safety Devices - EdilKamin DAME Instalación Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
THERMO TECHNICAL CHARACTERISTICS
Thermal power output
Yield / Ef ciency
Emissions CO 13% O2
Fume temperature
Fuel consumption
Hopper capacity
Draught
Autonomy
Heatable volume *
Smoke outlet pipe diameter (male)
Air intake pipe diameter (male)
Weight including packaging
TECHNICAL DATA FOR SIZING THE FLUE which must, in any case, comply with the guidelines of
this sheet and the installation rules for each product
Thermal power output
Temperature of fumes on exit from the discharge pipe
Minimum draught
Fume ow capacity
Classi cation of combustion chamber according to DIBt
* The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and subse-
quent changes together with an expected heat output of 33 Kcal/m³ per hour.

ELECTRICAL CHARACTERISTICS

Power supply
Average power consumption
Power consumption during ignition
Remote control frequency
Protection on electronic circuit board
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by quali ed personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
3) In case of problems with the electrical grid, consult an electrician to evaluate the installation of a sine-wave UPS of at
least 800 Va. Power variations greater than 10% can cause problems for the product.
The above data are indicative and are those resulting during certi cation on the part of the noti ed body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.

SAFETY DEVICES

• THERMOCOUPLE:
Placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on de ned parameters.
• VACUUM GAUGE:
Positioned on the smoke extractor, which detects the vacuum value (compared to the installation environment) in the combustion
chamber.
• SAFETY THERMOSTAT:
Trips when the temperature inside the stove is too high. It stops pellet loading, causing the stove to go out.
• SAFETY PRESSURE SWITCH:
This is activated if the vacuum inside the combustion chamber is insuf cient for it to function correctly.
GENERAL INFORMATION
according to EN 14785 (for other values, see DoP on page 35)
Nominal power
6
85,7
0,010
151
1,5
18
12 - 5
10
155
80
40
254
Nominal power
6
181
0 - 5
7,6
FB 22
230 Vac +/- 10% 50 Hz
120 - 150 W
400 W
Radio waves 2,4 GHz
T2A, 250 Vac, 5x20 Fuse
- 34
-
Reduced power
2,2
90,8
0,014
85
0,5
10 - 3
30
Reduced power
2,2
102
3,3
FC
52x
kW
%
%
°C
kg/h
kg
Pa
hours
3
m
mm
mm
kg
kW
°C
Pa
g/s
-
Tabla de contenido
loading

Este manual también es adecuado para:

Ania

Tabla de contenido