SCSI ID Setting

Option Switches (DIP Switch)

The SCSI ID is set by the rotary switch on the rear panel. Press the + or -
buttons to move the number up or down, respectively.
As shipped from the factory, the SCSI ID is set to 0. Press the switch buttons,
if necessary, to select the SCSI ID number you require.
Precautions
• The SCSI ID must be different from IDs of the other peripherals on the SCSI
bus.
• As shipped from the factory, SCSI parity is enabled and Term power is ON.
A SCSI bus terminator must be connected to the SCSI bus before use.
• Before changing the SCSI ID setting, be sure to turn off the power with the
POWER switch on the front panel.
Remove the two slotted screws by using a slotted screwdriver. Remove the
access cover to change the DIP switch settings. (Refer to the following
figure for details changing the DIP switch settings.)
After changing the DIP switch settings, replace access cover and tighten the
two slotted screws using a slotted screwdriver.
CAUTION
Before removing the access cover to change DIP switch settings on the drive,
turn off the computer and disconnect the power cord from the unit. Once the
DIP switch settings have been changed, replace the access cover using the
two original slotted screws provided.
Access Cover
DIP Switch
Part 2. Preparation
Slotted
Screws
13