Installation - EBARA 3TP Serie Manual De Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
13 - ENG
4.3.3. Liquid requirements for the pump.
The 3TP submersible pump was designed to pump cold and clean water, free from
ATTENTION
air or gas. If the characteristics of the liquid are not as described, the life span and
the characteristics of the pump could change.
Make sure that the minimum cooling flow on the pump is 8 cm/s. See the table below.
Do not let the pump run with the delivery pipe closed for more than 10 mins.. The
ATTENTION
motor would not be cooled and could overheat.
4.4
Selection of cable
The 3TP pump can be supplied with different cable lengths without any joints. If the cable
length is not sufficient, other lengths can be joined by using one of the special junction kits.
Always choose the appropriate cable section in order to have the exact voltage at
ATTENTION
the pump terminals. (Permitted variation: –10%/+6%) .The technician installing the
cable is the only person responsible for the choice of cable. The minimum section is
specified in the table below.
Maximum cable length according to the section with 230V and 4% voltage drop
Motor
600 W
900 W
1500 W
5.

INSTALLATION

During installation of the pump, care must be taken not to damage the cable. It
ATTENTION
should be protected if necessary.
When the pipe is fixed to the pump, this should be held by the upper support.
ATTENTION
Before doing any work on the pump, the power supply must be disconnected.
ATTENTION
5.1 Protection against electric shock (grounding/earthing)
To prevent electric shocks, the pump must be grounded in conformity with the current
legislation of the country in which it is being installed.
5.2
Vertical installation
Connection of the delivery pipes
ATTENTION
Always check the technical specifications of the pipe manufacturer.
If the pump was installed with plastic piping, when lifting, a steel cord should be hooked onto
the upper support of the pump.
Min flow for motor cooling in water up to 35°C.
Well diameter
[mm (inches)]
102 (4")
127 (5")
152 (6")
1,5 mm²
2,5 mm²
70 m
120 m
60 m
85 m
55 m
75 m
3"motor, cooling flow
8 cm/sec [m³/h]
1,1
2,4
4,0
4 mm²
180 m
125 m
90 m
6 mm²
270 m
190 m
140 m
Tabla de contenido
loading

Este manual también es adecuado para:

3tp 6003tp 9003tp 1500

Tabla de contenido