BATTERY GUIDE
The Energizer will automa cally reduce its power usage if the ba ery is star ng to
go fl at. This will be achieved by reducing the energy in each pulse and increasing the
interval between pulses.
Number of Pulses per minute
The Energizer stops pulsing if the ba ery drops below 20% to prevent damaging the
ba ery.
Gallagher Recommends:
•
Use 12 V deep cycle lead acid ba eries.
•
Ba eries of the same type and manufacture can be connected in parallel to
increase capacity.
•
Store ba ery in a dry place between 0
•
Do not leave ba eries below 50% charge (12.0 V) for a prolonged period of
me.
•
Ba eries must be in a well ven lated area while charging.
Ba ery Capacity
Required
PRODUCT SPECIFICATIONS
Power consump on
Stored Energy:
Output Energy:
Output Voltage (no
load):
18
Gallagher 3E4345 MB1000i MB1800i MB2800i Energizer User Manual
30
20
15
10
6
MB1000i
100 Ah
2
200 Ah
4
300 Ah
6
MB1000i
10 W powered by
15 V adapter
8 W powered by
12 V ba ery
10 J
7.7 J
8 kV
Ba ery Capacity
75% +
60 - 70%
50 - 60%
40 - 50%
20 - 40%
o
C and 30
o
C.
Full Power Opera on (days)
MB1800i
1.5
3
4.5
MB1800i
16.5 W powered by
15 V adapter
11.5 W powered by
12 V ba ery
18 J
12.4 J
8 kV
MB2800i
1
2
3
MB2800i
20 W powered by
15 V adapter
17 W powered by
12 V ba ery
28 J
15.6 J
8 kV