4. SCHEDULE MODE: Press HOUR, MIN and EVENT to modify time set-
tings. Press DEL to delete. Press ENTER after each modification.
5. AUTO MODE: The time, day, seconds, the load status and AUTO are
displayed.
6.0

MANUAL OVERRIDE

OVR1 and OVR2 is effective in the AUTO mode
a) HIGH Speed override button OVR1
When load is off:
1. First button press of OVR1 sets control to HIGH speed and starts a 5
minute countdown. Flashing 1H on display indicates manual change
to HIGH. Unit will stay HIGH until next scheduled change.
2. Second button press of OVR1 sets control to flashing HOLD OFF. Load
is OFF and all program settings will be skipped until 12:00am when
HOLD OFF is automatically cleared. Normal schedule will be followed
after 12:00am.
3. Third button press of OVR1 clears the HOLD OFF and pump remains
OFF until next schedule change.
When load is on HIGH speed:
1. First button press of OVR1 sets control to flashing HOLD OFF. Load
is OFF and all program settings will be skipped until 12:00am
when HOLD OFF is automatically cleared. Normal schedule will be
followed after 12:00am.
2. Second button press of OVR1 returns control to the HIGH speed
setting with a 5 minute countdown delay.
When load is on LOW speed:
1. First button press of OVR1 sets control to HIGH and starts a 5 minute
countdown. Flashing 1H on display indicates manual change to
HIGH. Unit will stay HIGH until next scheduled change.
2. Second button press of OVR1 sets control to flashing HOLD OFF. Load
is OFF and all program settings will be skipped until 12:00am when
HOLD OFF is automatically cleared. Normal schedule will be followed
after 12:00am.
3. Third button press of OVR1 clears the HOLD OFF automatically sets
control to LOW speed after a 5 minute delay with the unit at HIGH
speed.
b) LOW Speed override button OVR2
When load is off:
1. First button press of OVR2 automatically sets control to LOW speed
after a 5 minute delay with the unit at HIGH speed. Flashing 2H on
display indicates manual change to LOW is being delayed. After 5
minute delay, flashing L indicates manual override was used to set
LOW speed. Unit will stay in LOW until next schedule change.
2. Second button press of OVR2 sets control to OFF and pump remains
OFF until next schedule change.