FOR TECHNICAL SUPPORT: SOUTIEN TECHNIQUE : PARA COMUNICARSE CON EL SERVICIO TÉCNICO:
[email protected] 877.230.7874
24-HOUR IN-WALL MECHANICAL TIMER
711A, 711AA
MODEL#:
24-HOUR IN-WALL MECHANICAL TIMER 120VAC SINGLE POLE, WHITE
DESCRIPTION:
701A = WHITE, 701AA = LIGHT ALMOND
CONTACT RATINGS:
125VAC, 60Hz, 15A RESISTIVE & GENERAL PURPOSE, 1250W TUNGSTEN, 1/2 HP
! CAUTION !
RISK OF ELECTRIC SHOCK
Disconnect power at main panel prior to installing
or servicing this lighting control or the equipment connected to it.
INSTALLATION & WIRING INSTRUCTIONS
1. Switch off circuit breaker to disconnect power to the circuit.
2. Using a slotted screwdriver, carefully pry the provided face
plate from the body of the timer.
3. In existing installations, remove wall plate and switch. There
are three wires in the box as follows:
"HOT" wire = usually black
"LOAD" wire = usually red
"NEUTRAL" wire = usually white
4. Connect the HOT wire to the timer's black wire, the LOAD
wire to the timer's red wire and the NEUTRAL wire to the timer's
white wire. Wires should be twisted together and secured with
wire nuts (provided).
5. Replace all wires inside of the junction box by folding wires
around the sides, bottom and top of timer. Do not force.
6. Using the two provided screws, secure the plastic adapter
plate and timer assembly into the holes in the junction box
where the wall switch had been previously mounted. (see draw-
ing).
7. Carefully push the plastic snap-on face plate onto the timer
assembly.
8. Restore power to the circuit.
PROGRAMMING & OPERATING THE TIMER
MANUAL OPERATION: Turn lighting or fan ON and OFF using the slide switch as indicated on the face plate.
AUTOMATIC OPERATION: Begin with the slide switch in the OFF position. Notice the round dial in the center of the face
is marked in hours of the day and divided into AM and PM sections. Around the inside of the dial are moveable tabs, EACH
REPRESENTING 30 MINUTES. These tabs, when tilted outward, represent power ON. Tabs left inward represent power OFF.
1. Decide when ON and OFF times are desired. For example, ON at 6:00AM, OFF at 9:00AM. Push outward on all tabs in
the AM section between 6AM and 9AM, starting with the one after 6 and ending before the 9. This is a total of 6 tabs,
each representing 30 minutes, now you have set the switch to turn ON at 6AM and OFF at 9AM.
2. You may decide you want additional ON/OFF times. For example, ON at 7:30PM, OFF at 11:00PM. Push outward all
tabs in the PM section, starting with the one before 8PM and ending with the one before 11PM. This is a total of 7 tabs.
3. Set the correct time of day by rotating the dial clockwise until the arrow on the inner circle points to the correct time.
4. Push the slide switch to the "AUTO" position.
NOTE: The slide switch may be used at any time to override the automatic schedule. Simply slide the switch to ON or OFF as
desired. Remember to return the switch to the "AUTO" position again when automatic programming is desired.
ONE YEAR LIMITED WARRANTY: If this product fails because of a manufacturing defect within one year after purchase, we will, at our option, either repair or replace it at no
charge. Our warranty does not cover damage caused by accident, abuse or misuse. We assume no further liability with respect to the sale or use of this product. THIS WARRANTY
IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTY OF MERCHANTABILITY. We make no warranty with respect to the fitness of any
goods for the users particular appplication. This warranty gives you specific legal rights, and you also may have other rights which vary from state to state.
It is our intent to provide accurate and current specification information. However, in the interest of product improvement, TORK may alter the specifications or constructional details
without prior notice.
NSI INDUSTRIES, LLC • 877.230.7874 • www.nsiindutries.com
LI-792(B)
This timer is designed to fit a standard (min. 2 1/2" deep) electrical
junction box in new construction or to replace an existing wall switch.
It is used for the automatic control of a lighting circuit or motor driven
device such as a ceiling or attic fan. It is recommended that installation
be done by an electrician.
TIMER