Press Key 3 from the external keyboard and confirm with "ENTER".
Magnetron/fan power supply relay test.
a) When you press "ENTER" you activate and deactivate the magnetron power supply relay.
Press "ESC" once only in order to test the power supply to the fan.
b) When you press "ENTER" you activate and deactivate the ventilation system.
Press Key 4 from the external keyboard and confirm with "ENTER".
Delivery position test: The motor moves the oven until it takes it to the product delivery position.
Press Key 5 from the external keyboard and confirm with "ENTER".
Rest position (HOME) test: The motor moves the oven until it takes it to the home position, i.e. the product
acceptance position.
Press Key 6 from the external keyboard and confirm with "ENTER".
Heating position test: The motor moves the oven until it takes it to the product heating position.
Attention: you pass through the expulsion position when you move from the heating position to the
home position.
Press Key 7 from the external keyboard and confirm with "ENTER".
Oven chamber cover movement test: The oven cavity is taken to the heating position. The cover is closed
or reopened every time you press the "ENTER" key.
Press Key 8 from the external keyboard and confirm with "ENTER".
Anticlockwise rotation test: When the confirmation key (ENTER) is pressed again, the motor moves the
oven in an anticlockwise direction; the oven stops when the key is released.
Press Key 9 from the external keyboard and confirm with "ENTER".
Clockwise rotation test: When the confirmation key (ENTER) is pressed again, the motor moves the oven
in a clockwise direction; the oven stops when the key is released.
Press Key 0 from the external keyboard and confirm with "ENTER".
The following option can only be used if you put a product to be heated inside the oven cavity and if the cavity
is in the heating position. If these indications are not followed, the oven may be damaged irremediably.
Heating time test: enter the heating time in seconds and then confirm by pressing "ENTER". Default = 0 (no
heating) and it can be set between 0 and 120 sec. The magnetron is activated and produces microwaves that
heat the product.
Command 79 Test for door locking device:
By pressing anyone of the keys, except for ESC, it is possible to make sure that the delivery door locking
device is operating.
Command 80 Cloning:
This command makes it possible to transfer all the parameters of the vending machine to a "Program Key",
to program same model machines. When you enter the command "Write Clone Key" appears on the display.
Then, enter the "Program Key" and press the ENTER key. "Data Writing...*" appears on the screen while the
data is being transferred to the key. Once the data transfer operation is completed, the machine returns to
the programming mode.
Caution: DO NOT enter the key before entering the programming mode, otherwise the vending machine will
fetch the data existing in the key.
Command 81 Fetch vend data:
This command makes it possible to transfer all the EVA-DTS data to a "Program Key". This data can be
extracted using special software (VMC configurator). The maximum number of possible registrations is 100.
Attention: if the key is not recognised as a data key, at the first registration the user will be asked to confirm
the complete deletion of the existing data.
Command 85 Display of checksum and main and power board software version.