taBle 2. aDvanceD conFIGUratIon (cont.)
menU
FeatUre
Intermittent Fan On
501
Time
Intermittent Fan Off
502
Time
Default Display Icons
520
Revision
530
Factory Default Reset
540
System Test Main
600
Output (Cool)
System Test Main
610
Output (Heat)
System Test Fan
620
Output
note: For Service Menus 610 and 620, outputs will be activated based upon the system configuration.
© COPYRIGHT 2010 PECO, INC. ALL RIGHTS RESERVED.
oPtIons
stD.moDel
DescrIPtIon / comments
DeFaUlt
1-60 minutes
5 minutes
Defines the on time for the Intermittent Fan.
0-60 minutes
25 minutes
Defines the off time for the Intermittent Fan. Select 0 for continuous fan.
0-4
0
Select icons that will be displayed in the Default Display screen.
0 =
1 =
2 =
3 =
4 =
Displays firmware revision information (for technician); not adjustable.
0,1
0
Select 1 (enable) to restore factory default settings for thermostat. Select 0 to disable.
0 =
1 =
Note: Press "Done" key to complete process.
0
0-2
Select an option to activate the fan output for 10 minutes; select 0, Done or a different Service Menu to
disable.
0 =
1=
2 =
0-3
0
Select an option to activate the fan output for 10 minutes; select 0, Done or a different Service Menu to
disable. note: Outputs will be activated based upon the system configuration.
0 =
1 =
2 =
3 =
0,1
0
Select 0 or 1 to activate the fan output for 10 minutes; select 0, Done or a different Service Menu to disable.
0 =
1 =
Time, Temp, Setpoint (SP)
Time, Temp
Time
Temp
None
Disable
Enable
Disable (Default)
Cool Stage 1
Cool Stage 2
Disable (Default)
Heat Stage 1
Heat Stage 2
Heat Stage 3
Disable Fan Output
note: Outputs will be activated based upon the system configuration.
Enable Fan Output
8