Gas Cylinder Safety Information; Leak Testing Procedure - Fulgor Milano FOBQ 1000 G X Instrucciones Para La Instalación Y El Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6 - Gas cylinder safety information

EN
• When converted for the use of universal
LPG, the appliance is designed to use
different types of cylinders depending on
the installation made. See the chapters on
Installation Preparation and Connection of
the cylinder.
• The gas cylinder must be manufactured and
marked in accordance with the specifications
for LPG cylinders.
• The shut-off valve must be closed when the
appliance is not in use.
• The gas cylinders must be kept in an approved
housing out of the reach of children.
• When you disconnect the gas cylinder, make
sure all the control valves are in the "OFF"
(O) position.
• Before disconnecting, remove the cylinder
from any housing in which it may be located.
• When you reconnect the hose to the cylinder,
make sure all the connections are tight before
placing it back in its compartment.
• After each connection of a cylinder, perform
a leak test as described below.

Leak testing procedure

• Make sure that all the gas taps are in the
"OFF" (O) position.
• Mix a solution of water and detergent or
soap in a small container.
• After connecting the hose, open the valve on
the gas cylinder or gas system tap.
• Using a brush, paint the solution on the gas
connection points and check for bubbles.
• Bubbles indicate a leak.
• Close the valve and tighten the fitting, possibly
inserting a new gasket. Repeat the leak test.
• If the leak persists, turn off the gas and contact
an authorized gas system maintenance
technician to repair the leak.
14
Tabla de contenido
loading

Este manual también es adecuado para:

Fobq 1000 g mbkFobq ll 1000 xFobq ll 1000 mbk

Tabla de contenido