• Automatic filter change warning, in order to inform
the user that proper maintenance must be carried
out to guarantee the quality of water produced. The
equipment must undergo a proper maintenance and
it will remain blocked until maintenance is carried
out.
• The system is ready for quick and easy connec-
tion of an automatic membrane cleaning valve.
This valve performs sweeps on the surface of the
membrane in order to drag accumulated deposits
and extend its lifespan.
3.1. MAINTENANCE AND CONSUMABLES
It is important that the maintenance is performed by
a team official service, which will use original spare
parts and provide information, a maintenance contract
and a guarantee of service. Any manipulation of the
equipment or use of non-original components by com-
pany or person outside our official distributor will void
your warranty.
The lifetime of consumables depend on the use that is
given to the appliance, the consumption of water, local
4. INTERFACE. SYSTEM STATUS
PJK-260
VISUAL INDICATION
GREEN
GOOD
RED
SERVICE
TEST
x1
GREEN
GOOD
RED
x1
SERVICE
TEST
x1
GREEN
GOOD
RED
x1
SERVICE
TEST
x2
GREEN
GOOD
RED
SERVICE
TEST
GOOD
GREEN
x3
SERVICE
RED
TEST
* Contact your service.
** When you detect any of the states described abo-
ve, contact with the maintenance service to arrange
appointment. See the relevant section in the Manual
Technical.
Contact your service if the unit does not stops pro-
ducing water (after completely filling the tank) after
several hours, without any water extraction.
Contact your service if the unit blocks repeatedly due
ACOUSTIC
INDICATION
-
to low water pressure and having pressure water on
the rest of the house.
Contact your service if , after opening the faucet, the
unit would find at rest, without dispensing water using
the tap or showing any alarm.
The beeps are not continuous; they last a few seconds
(10 "). While maintenance state is maintained it will be
indicated by LEDs on the panel and acoustic notifica-
tion periodically every 7 hours.
19
waters quality and other such as extreme turbidity,
high chlorination, iron excess, etc ...
An excess in a water compound (total chlorine, tur-
bidity, hardness, etc ...) can cause a reduction in the
life of filters and certain components. This lifespan is
approximate. Read the corresponding section of the
Technical Manual. Your dealer will provide for con-
sumable life depending on your water quality and the
expected consumption.
Warning: To ensure the quality of water supplied by
your appliance, periodic maintenance must be per-
formed by qualified personnel. The equipment must
be sanitized periodically according to use and predicted
water consumption.
Warning: Some appliance components, such as carbon
pre-filter, post-filter and reverse osmosis membranes,
have a limited duration.
MEANING
After pressing "TEST" button, green led "GOOD", will light per-
manently while the quality of the water is optimal.
After pressing "TEST" button, green led "GOOD" and the red
LED "SERVICE", will blink indicating water quality is decrea-
sing.
After pressing "TEST" button, green led "GOOD" and the red
LED "SERVICE" will blink and a acoustic signal will be emitted
(once and after every 7 hours) indicating there is a water leak.
After pressing "TEST" button, green led "GOOD" will blink
twice while the red LED "SERVICE" remain continuously illu-
minated indicating that soon should proceed to change the
filters. **
After pressing "TEST" button, green led "GOOD" will blink
three times while the red LED "SERVICE" remain continuously
illuminated and a acoustic signal will be emitted (once and
after every 7 hours) indicating filters change is required. **