3. HOW THE EQUIPMENT WORKS
• The mains water to be treated is fed through the equi-
pment after passing through the pre-filtering stage that
incorporates a turbidity (S) and carbon filter (C). During
this filtering stage, chlorine, its derivatives and other
organic substance particles are retained.
• Water flow towards the appliance is controlled either
by a 4 ways shut off valve (So) or by a solenoid valve (Si)
(depending on the model).
• The unit with a pump (PUMP) have a built-in low pres-
sure switch to protect the pump against pressure drops
from the network (LPS).
• After the filtering stage, water flows towards the
reverse osmosis membrane (M). Depending on each
model, the appliance may incorporate a pump (P) to in-
crease pressure. It is the effect of the water pressure
upon the membrane, which makes the reverse osmosis
possible.
• The treated water is stored in the tank (T) for its sub-
sequent use. Water that is rejected or has excessive salt
or other dissolved substances flows towards the drain
Technical Information
PUMP
24 Vdc
Hydraulic connections diagram
* For salinity levels above 2000 ppm, please check with your distribu-
tor. Warning: a high salinity rate and/or low entry pressure may cause
the machine to operate outside of its working limits thus substantially
FAUCET
DRAIN
IN
limiting or preventing the reverse osmosis process.
** Higher levels of hardness can reduce the service life and correct
function of certain components.
***Maximum accumulation may vary depending on the model.
**** Flows can vary by up to 20% in function of the temperature, pres-
sure and specific composition of the water to be treated.
***** Possible variations depending on the model chosen.
MANUFACTURED BY:
PURICOM INDUSTRIAL WATER CORPORATION (Taiwan)
DISTRIBUTED BY:
IONFILTER. PURICOM EUROPE. PURICOM AMÉRICA
Pol. Ind. L'Ametlla Park. C. Aiguafreda, 8.
08480 L'Ametlla del Vallès. Barcelona (Spain)
T. 902 305 310 F. +34 936 934 329
LPS
HPS
PJK
L
260
Q
outlet (G) to be disposed of.
• The equipment with a pump (PUMP) control the filling
of the tank via a pressure switch (HPS).
• When the system's tap is turned on, the water stored in
the tank flows through a post-filtering stage (R) whose
aim is the elimination of possible odours and taste, as
well as pH level adjustment (depending on the model),
which the water may retain before being dispensed.
• Depending on the model, the appliances may have di-
fferent functional and/or safety systems, managed by a
state-of-the-art electronic module:
• Electronic system for leakage detection (L). When
the system detects this condition, it blocks the system
and emits an acoustic signal and a light signal to in-
form about the situation. The unit will remain blocked
until the leakage sensor is dry.
• Probe used to estimate the conductivity of water
produced, thus assessing the state of the membrane
and the components (Q). Press the front button to me-
asure the conductivity of water produced.