length, as reverse polarity and/or overcharge conditions will occur.
usinG tHE 50 AMP BAttErY cLAMPs
1.
connect the end of the charger output cable to the end of the battery
cable quick-connect and clamps.
2.
follow the steps in sections 6 and 7, to connect the output clamps to
the battery.
3.
connect the charger to a live grounded 230V Ac outlet.
usinG tHE rinG connEctors
1.
to permanently attach to a battery, loosen and remove each nut from
the bolt at the battery terminal.
2.
connect the red PositiVE connector ring to the PositiVE battery
terminal.
3.
connect the black nEGAtiVE connector ring to the nEGAtiVE
battery terminal.
4.
replace and tighten the nuts to secure.
5.
connect the cable to the end of the charger output cord.
take care to keep the wires and plug away from metal and moving
parts.
6.
connect the charger to a live grounded 230V Ac outlet.
BAttErY cHArGinG tiMEs
ccA = cold cranking Amps
BAttErY siZE/rAtinG
sMALL BAttEriEs
Motorcycle, garden tractor, etc.
cArs AnD
trucKs
times are based on a 50% discharged battery and may change, depending on
Ah = Amp Hour
200-315 ccA
• 12 •
cHArGE tiME
6-12 Ah
12-32 Ah
36-46 Ah
(1A)
3¾-7½ h
7½-20 h
18-25 h