Error Messages And Solutions - AccuBANKER Silver S6500 Guía De Usuario

Contadora compacta de billetes mezclados
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Error messages and solutions

ERROR
MESSAGES
Count Sensor
Error R
Count Sensor
Error L
Stacker Sensor
Error
Hopper Sensor
Error
Speed Sensor
Error
OPEN TOP COVER
CLEAR CHANNEL
POSSIBLE CAUSE
Top compartment opened or
problem with the right sensor
Problem with the left sensor
Stacker sensor dirty or damaged
Hopper sensor dirty or damaged
Top Compartment open
Bill Jammed Inside
Bill jammed inside the unit
motor damaged
SOLUTION
Clean the sensor
Close the top compartment
Clean the sensor
Close the top compartment
Clean the sensor
Contact with tech support
Clean the sensor
Contact tech support
Verify there is
bill jammed
no
Close the top compartment
Verify there is no bill jammed
Close the top compartment
Press START to clean the error