Motorline professional SP SHUTTLE 60/100 Manual De Usuario página 16

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MAINTENANCE
No particular maintenance is required to the Central.
Verify at least twice a year if the Door is properly balanced and if the moving parts are in good condition.
NOTE: A door that doesn't matches the requirements due to incorrect loads can affect the engine's lifetime and will void the warranty.
Check at least twice a year the reversing sensitivity and adjust if necessary.
Make sure that the safety devices are working effectively (photocells)
TECHNICAL DATA
Power Input: 230V AC +/- 10% 50Hz
MOTOR: 24V DC
Courtesy light time: 3 minutes
Operation Temperature: -20º~70º
Relative Humidity: <90%
Open and close force: 600N in the SP SHUTTLE 60 version, 1000N in the SP SHUTTLE 100
Reception frequency: 433.92Mhz
Sensitivity: greater than 1V for correctly received signal (average range 30Mts)
Decoding: Rolling Code or Dip Switch
Max. door area to be automatized: SP SHUTTLE 60 (600N): 8M2; SP SHUTTLE 100 (1000N): 14M2
NOTE: MOTORLINE has the right to modify its product at any time without notice.
FINAL NOTES
This manual is intended to be used only by technical personnel, with qualification to carry out the installation. No information given in this
manual can be considered of any interest to the end user. No settings or adjustments contained in this manual can be carried out by the end
user. It is important for the installer to show their clients the correct operational use of the MOTORLINE device, including the manual
disengagement cord.
Inform the owner about the need for a regular and accurate maintenance, especially regarding a regular check of the safety and reversing
devices.
TIPICAL APPLICATIONS
The MOTORLINE device (with standard rail) can automatize sectional overhead doors up to 2300mm. In case of a higher door, MOTORLINE sells
rail extensions, increasing the maximum height up to 3300mm.
USER INFORMATIONS
Once the MOTORLINE opener has been installed, the user must be informed about how it works and all the risks that can come from an
improper use. The user must avoid placing himself in dangerous situations, such as standing within the door's operating range when moving.
Do not let children play near the door and keep the remote controls out of their reach.
All servicing, repairs or checks must be carried out by professionally qualified personnel and noted on a maintenance register kept by the user.
In case of malfunction, the user must call the installer and not attempt to repair it.
MANUAL DISENGAGEMENT
The MOTORLINE opener is equipped with a manual release cord for disengaging the motor from the door (Fig. 09), This operation must be
carried out only in case of power failure or device malfunction.
Pág. 16
Tabla de contenido
loading

Tabla de contenido