Service - Dustcontrol DC 2800c Manual De Instrucciones

Ocultar thumbs Ver también para DC 2800c:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25

Service

During cleaning and service of the unit, the unit
should be disconnected from the power supply.
The fi ne fi lter should be changed at least once per
year. Use only original parts for replacement. If the
unit is equipped with a HEPA fi lter, this fi lter should
be changed every 300 working hours. Use breathing
protection and perform this operation in a contained
area. The used fi lter should be placed in contain-
ment and disposed of in the proper and prescribed
method.
Filter change:
Remove the motor head. Lift the fi lter straight up out
of the cyclone. When required, a plastic sack can be
placed over the cyclone for dust-free fi lter change.
The fi lter is lifted directly into the sack.
During the fi lter change, check the fi lter gasket. A
damaged gasket can allow the release of hazardous
dust. Never use old gaskets or after-market fi lters. Use
only genuine Dustcontrol spare parts to maintain the
unit for use on hazardous dusts.
Check regularly that the electrical cable is not dam-
aged. The DC 2800c should be performance tested
at least once per year because it may be used with
hazardous materials. Worn parts must be replaced.
The vacuum motor is maintenance free.
Filterchange HEPA fi lter:
1.
2.
Part No. 42027
4.
5.
7.
3.
6.
DC 2800c, 11
Part No 94112
Tabla de contenido
loading

Este manual también es adecuado para:

94112

Tabla de contenido