Maintenance Instructions: AerosoL 3
Telescopic Lance
Replacing a damaged pole section:
When ordering replacement pole sections, they are referenced as follows:
• Section 1 (Butt section) Part Ref: ARL3-23.
• Section 2 (Middle Section) Part Ref: ARL38-06.
• Section 3 (Top Section) Part Ref: AL3-01.
1. Remove the clear PVC gasket from the
flexible tip and remove the internal tubing
kit by pulling out through the base of the
lance. Then remove the rubber end cap.
3. Insert the new section by sliding
it back into the lance.
5. Refit the clear PVC gasket and then
put the top section back inside the lance.
For detailed videos on the maintenance process see:
PVC gasket.
4. Straighten the flexible tip and feed through
the rubber end cap. Next push the flexible
tip and tubing back through the top section
of the lance (Make sure the flexible tip is
straight to enable it to be pulled through the
PVC gasket.
6. Slide the rubber end cap back onto
www.lancelab.com
2. Remove the damaged section
from the lance.
top section).
the bottom of the lance.
EN