RIB RED Manual De Instrucciones página 18

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

G
B
POINT C
- ASSEMBLY
Install the RADIO EDGE RECEIVER near the RIB gate/door electronic
board.
Secure the safety strips in the conveyance or deflection area, depending on
gate/door high (max. 2.5m) and secure one RADIO EDGE TRANSMITTER
per each nearby.
Connect each safety strip contact to the J3 terminal of its RADIO EDGE
TRANSMITTER.
Both NO or NC safety strip contact may be used, hence select trough the
JP2 jumper the type of contact used.
It's strictly necessary to connect a 8.2kΩ 1/4w resistor in series (if
the safety strip contact is NC) or in parallel (if the safety strip contact
is NO).
MECHANICAL SAFETY STRIP connection
R = 8,2 KΩ
ELECTRICAL SAFETY STRIP connection
18
18
18
18
R = 8,2 KΩ