Required:
• Flathead screwdriver or 5/16" (8 mm) nut driver.
• If solar collectors are placed farther than 6 ft. (1.829 m) from your
pool equipment, you will need to purchase sufficient hose
or pipe to connect the collectors to your pool equipment.
White End Cap
Labels
Black Rubber Connector Hose
White End Cap
1. Provide an area that is free of any sharp objects with at least 6 hours of full sunlight a day.
2. Remove strap from collectors and unroll them next to each other placing the headers with the serial
number labels away from your pool equipment (as shown above).
3. Allow the collectors to relax in the sun (30 minutes to an hour). DO NOT LAY COLLECTORS ON
THE GRASS IT CAN DAMAGE THE LAWN UNDERNEATH! DO NOT WALK ON COLLECTORS.
4. Remove and discard the black protective end caps covering the threaded ends of the header pipes.
5. Join the headers with the labels together using one black rubber connector hose and two 1 1/2" (3.81 cm)
hose clamps. Position hose clamps 1/2" (1.27 cm)) in from each end of rubber connector hose and tighten
(as shown). Do Not Overtighten. Do not push connector hose against tubes of collector.
6. Wrap the 6 remaining threaded ends of the headers with Teflon tape provided
(as shown) for a watertight seal.
7. Thread white end caps on the open ends of the headers with the labels (as shown).
8. Join the headers without the labels together using the diverter valve provided (as shown).
9. Thread elbow connectors on the open ends of the headers without the
labels (as shown). Be careful not to cross-thread.
10.Turn off pool pump.
11. Go to pool and plug the round return fitting on the pool wall from the
inside so the water won't drain through (a winter plug works well).
12. Remove the hose that is clamped to the filter outlet and the back of the return fitting.
13. With one of the flex hoses provided, clamp one end to the filter outlet and the other end
to lower elbow adapter. (Do Not Overtighten) Always fill the system from the bottom.
14. With the other flex hose provided, clamp one end to the other elbow connector and the
other end to the return fitting on the outside of the pool wall.
15. From the inside of the pool wall, remove the plug you placed in the round return fitting.
YOU ARE NOW READY TO START-UP YOUR SOLAR POOL HEATER
16. Turn on the pump. Check for leaks and tighten the connections that need attention.
Note:Upon start-up you will see air bubbles come through the return hose.
This is normal and will stop after all the air has been purged from the solar heating system.

SYSTEM LAYOUT

Single Box
Elbow Connector
Diverter Valve
Elbow Connector
6
8
Warm Water
Cool Water
(Return Fitting)
(Feed)
Filter
Pool Pump
Diverter Valve
Solar On
Solar Off
5
7
9
Tabla de contenido
loading

Tabla de contenido