ENGLISH
6.3
CONTROL PANEL
WARNING: It is forbidden to alter pressure parameters without
authorisation from AEROTECNICA COLTRI.
Any unauthorised modifications shall render the warranty
null and void.
1 Automatic shutdown pressure switch
The automatic shutdown pressure switch (1) determines the compressor
shutdown pressure.
The shutdown pressure can be set via the regulator compressor reaches
the set pressure it shuts down automatically.
The compressor can reach a maximum pressure of 232-300-330 bar
(3300-4300-4700 PSI).
2 1
stage pressure gauge
st
Indicates the pressure inside the 1
3 2
stage pressure gauge
nd
Indicates the pressure inside the 2
4 3
stage pressure gauge
rd
Indicates 3
compression stage pressure and final refill pressure.
rd
1
1
MU-EVOLUTION-0419
compression stage.
st
compression stage.
nd
4
a
ESPAÑOL
6.3
PANEL DE MANDO
ATENCIÓN: Se prohíbe modificar los parámetros de presión
sin autorización de AEROTECNICA COLTRI so pena el
vencimiento de la garantía, caso que el compresor aún esté
cubierto por la misma.
1 Presóstato
El presóstato para el apagado automático (1) indica la presión de
apagado del compresor.
La presión de apagado del compresor puede configurarse interviniendo
sobre el regulador (a) y aparece en el indicador (b). Cuando el compresor
llega a la presión programada éste se apaga automáticamente.
El compresor puede llegar a una presión máxima de 232-300-330 bar
(3300-4300-4700 PSI).
2 Manómetro primera etapa.
Indica la presión dentro del primera etapa de compresión.
3 Manómetro segunda etapa
Indica la presión dentro del segunda etapa de compresión.
4 Manómetro tercera etapa
Indica la presión del 3er. estadio de compresión y de la presión final de
recarga.
3
EVOLUTION
2
37 - 60