3.2 - MODELS AND TECHNICAL FEATURES
CODE
DESCRIPTION
12006685
BIOS1 24V control unit for a single motor
60550058
Transformer 230 / 23 Vac 150VA
12006730
Bluetooth module
12000760
R1 card
12000780
Battery charger 24CBA card
Transformer power supply
Fuse for transformer protection
BIOS1 24V power supply
Maximum power of the motor output
Flashing light output
Courtesy light / Open automation light output
24Vdc accessories power supply
433MHz radio receiver
Memorisable transmitters
Operating temperature
3.3 - LIST OF THE SUGGESTED CABLES
The suggested cables for the connection of the various devices in a standard system are listed in the following list.
The used cables must be suitable for the type of installation; for example, an H03VV-F type cable is recommended for indoor applications, while
H07RN-F is suitable for outdoor applications.
Connection
Line for the power supply
Motor
Flashing light
Courtesy light / Open automation light
Photocells - transmitter
Photocells - receiver
Safety edge
Key selector
* If the cable is more than 20 m long, it must be of larger gauge and a safety grounding system must be installed near the automation unit.
3.4 - PRELIMINARY CHECKS
- The gate shall move frictionless.
Note: Gate features must be uniformed with the standards and laws in
force. The door/gate can be automated only if it is in a good condition and
if its conditions comply with the EN 12604 norm.
- The door/gate leaf should not have a pedestrian opening. In the opposite
case it is necessary to take the appropriate steps, in accordance with EN
12453 norm (for instance: by preventing the operation of the motor when
the pedestrian opening is opened, by installing a safety microswitch
connected with the control panel).
- Besides the electrical or mechanical limit switches available on the
operators, there must be, on both ends of the installation, a fixed
mechanical stopper which stops the gate in the unlikely event of bad
functioning of the limit swithces on the operators. For this reason the
fixed mechanical stopper must be of an adeguate size to withstand the
static and kinetic forces generated by the gate (A) (Fig.2).
The guide must be provided with two mechanical stops at its ends (A)
(Fig. 2).
- The gate columns shall have anti-derailment guides on their top (Fig. 3),
4/20
Cable
3 x 1,5 mm 2
2 x 1,5 mm 2
2 x 0,5 mm 2
2 x 0,5 mm 2
2 x 0,5 mm 2
4 x 0,5 mm 2
2 x 0,5 mm 2
4 x 0,5 mm 2
A
ITA
ENG
FRA
230Vac 50-60Hz
T 1A
24Vac 50-60Hz
240W
24Vac 25W
24Vac 25W
24Vdc 5W
Rolling Code
1000
-10°C +55°C
Maximum lenght
20 m *
20 m *
20 m
20 m
20 m
20 m
20 m
20 m
ESP
6-1622400
A
FIG. 2
rev.03
07/09/2018