Technical Data; General Data; Measuring Signal Inputs; Control Inputs Mpi 1 / Mpi - Kübler CODIX 566 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

11 Technical Data

11.1

General Data

Display:
Digit height:
Data retention:
Operation:
11.2

Measuring signal inputs

Sampling rate:
Input resistance:
Max. measuring
signal range:
Max. voltage
Strain gauge signal input
Sensitivity:
Resolution:
Measuring accuracy typ. 0.05 % of range
@ 23°C:
Temperature drift:
Sensitivity:
Resolution
Measuring accuracy typ. 0.1 % of range
@ 23°C:
Temperature drift:
11.3

Control Inputs MPI 1 / MPI 2

Quantity:
Function:
Switching levels:
Pulse length:
11.4

Alarm outputs

Relays:
Switching voltage:
Switching current:
Switching capacity: max. 1250 VA / 150 W
Mechanical service life (switching cycles)
N° of switching cycles at 5 A / 250 V AC
N° of switching cycles at 5 A / 30 V DC
11.5

Supply voltage

AC supply:
DC supply:
Page 18
6-digit, 14 segment LED
14 mm
> 10 years, EEPROM
5 keys
10 readings/sec
1 M
approx. ± 35 mV
±10 V.
3.3 mV/V; 3.0 mV/V;
2.0 mV/V
± 15 Bit
max. 0.1 % of range
< 100 ppm/K
1.5 mV/V; 1.0 mV/V
± 14 Bit
max. 0.2 % of range.
< 100 ppm/K
2, optocouplers
programmable
Low: < 2 V
High: > 4 V (max. 30 V)
>100 ms
changeover contacts
max. 250 V AC / 125 V DC
min. 5 V AC / V DC
max. 5 A AC/ A DC
min. 10 mA
90 ... 260 V AC / max. 9 VA
50 / 60 Hz
ext. fuse protection: T 0.1 A
10 ... 30 V DC / max. 3.5 W
with galvanic isolation and,
reverse polarity protection
ext. fuse protection: T 0.4 A
Mains hum
suppression:
11.6
AC supply:
DC-supply:
11.7
Operating temperature: -20°C ... +65°C
Storage temperature:
Relative humidity:
Altitude:
11.8
Noise immunity:
Noise emission:
11.9
Designed to:
Protection Class:
Application area:

11.10 Mechanical Data

Housing:
Dimensions:
Panel cut-out::
Installation depth:
Weight:
Protection:
Housing material:
Vibration resistance: 10 - 55 Hz / 1 mm / XYZ
EN60068-2-6
Shock resistance:
EN60068-2-27
EN60068-2-29
Cleaning:
7
1x10
4
5x10
4
5x10

11.11 Connections

Supply voltage and outputs:
Plug-in screw terminal, 8-pin, RM5.00
Core cross-section, max. 2.5 mm²
Signal and control inputs:
Plug-in screw terminal, 9-pin, RM 3.50
Core cross section, max. 1.5 mm²
50 Hz or 60 Hz,
programmable

Sensor supply voltage

24 VDC 15 %, 30 mA
10 VDC 1 %, 30 mA
10 VDC 1 %, 30 mA

Climatic Conditions

-25°C ... +75°C
R.H. 93 % at +40°C,
non-condensing
up to 2000 m

EMC

EN61000-6-2
with shielded signal and
control cables
EN55011 Class B

Device Safety

EN61010 Part 1
Protection Class 2
Pollution level 2
Panel mount housing
to DIN 43 700, RAL 7021
96 x 48 x 102 mm
+0.8
92
x 45
approx. 92 mm incl. terminals
approx. 180 g
IP 65 (front)
Polycarbonate UL94 V-2
30 min in each direction
100G / XYZ
3 times in each direction
10G / 6 ms / XYZ
2000 times in each direction
The front of the unit should
only be cleaned using a
damp (water!) cloth.
+0.6
mm
Tabla de contenido
loading

Tabla de contenido