Function Groups

9.1

Help Texts (running text)

Help Text menu
Select Help Text
ON
- a running text that has
started can be aborted with
any programming key
OFF
Select language for Help Text
English
Deutsch (German)
9.2

Signal inputs

Menu Input Signal
Select measuring range
Sensitivity 3.3 mV/V
Sensitivity 3.0 mV/V
Sensitivity 2.0 mV/V
Sensitivity 1.5 mV/V
Sensitivity 1.0 mV/V
Select lower measuring range
limit
Input range
0.00 ... -105.00 [%]
Select upper measuring range
limit
Input range
0.00 ... +105.00 [%]
Select decimal point
(optical function only)
0
0.0
0.00
0.000
0.0000
Select input low value
Input range
-105.00 ... +105.00 [%]
Select display low value for
INP.LO.
Input range
-199999 ... +999999 and DP
Select input high value
Input range
-105.00 ... +105.00 [%]
Select display high value for
INP.HI.
Input range
-199999 ... +999999 and DP
Select Input Filter
The Filter function shows how
many measurement cycles are
used to determine the moving
average.
Input range 1 ... 99 [cycles]
- with a value of 1 the filter
function is switched off
Select Start Delay after Power
On
(limit monitoring is processed
only after the programmed
time has expired)
Input range 0.0 ... 99.9 [sec]
Select local mains frequency
Mains frequency 50 Hz
Mains frequency 60 Hz
The input range for the input values is
entered in %. This means that with a
sensor voltage of 10 V and a sensor
sensitivity of 3.3 mV / V then 33 mV
equate to an input value of 100 %.
The functions LO.LIM and HI.LIM limit the
editable range.
The value for HI.LIM must always be
greater than the value for LO.LIM.